Conditions of Demolition/Moving
4' construction fencing shall enclose existing basement perimeter and
excavations with slopes steeper than 1:1. Attach fencing to minimum
5' posts buried 1' and spaced at a maximum 10" on center.
Enclose stockpiled soils with properly installed silt fencing.
Property must be restored within thirty (30) days of building
demolition/move - utilities abandoned at the property line with a
permit, foundation demolished with a separate permit, debris
removed, demolition excavation filled to match adjacent grade and
seed or sod placed and maintained at disturbed areas OR a permit
must be issued for a new structure within thirty (30) days of the
building demolition/move.
it
Engineering Iabrio
SILT FENCE MUST BE
INSTALLED PRIOR TO
DISTURBING
VEGETATION
Fabrlo anchorage
Venal Per:WM*1h
../7- tamped nalural solt
-61nr.tt rniatimigh
,
6 inch minimum
Confirm property may be
Redeveloped prior to demolition
A demolition permit provides no
Assurance of permitted future uses
N 8953'27" E
--72. 71--
CATCH BASIN (ELEV.T907.0)
-"" 907.0_, _
X921.2
)419.3
1
Metal or
Post Or slake
DirectiOh of
runoff 'Prow
Natural soli
Wire awe, minims
(optional)
X920.8 \
S5S55555 '555
\
fr) 1
CO (Xi,'
• C1,)
927_ • t
_X922193.11:
2.
X422:0 '
X915.5
-1- -
- _
X92,i3 X925.1
▪
' 927- _
9274 -Fence 927.9
I
1,4 biaple
X9i3.21
923.7 I :
H
/ / , ri /', 14
1 9241.!2v\ ' ' 1
, /
923.3 9:4.8
0 /
92,4.9
' ?24t6
, 1
io
ra IV ro , Cri is,
3.11 1
‘,:,,, ,
"Z '1 th i,
928
9276'
928.55,9.54,
Afrmlo t ‘,F;aciel'ori.,r413
1t• Wa11928 9267 927 1.1
eleieliMin Mi id IR eeplen MW.n
Note; Depending upon configuration, atiacia Tabtrio to wire meth with
nog rings, etee3 poste with tle wires, or wood posis with staples_
Figure 6,3-2: Typical Postailatron tor 51111 fence
;928.1 928,
P.5
Sac c
93
91.2
930.gle-
CD GARAGE
929 930,
_
X9215 _ _ _929_
-929.9 ' X
X 930,5
31;LCOnC.
930.5
GARAGE FLOM ELEV.-931.p
30.4
X9294-30.0 X930.4 '
, , 930.31 1300 \
X922,4\1‹ McOle
930)
na;•,°.,
X929.8
Z_C
18" Oak@
929A X
929
r
-Se 927.7
93
'
25.9‘ 925
-e7S-
929.6 8.5 \
931
)4921.0
,•926.0
X930.6
4o 210%!miimmiimmiii0 10 20
GRAPHIC SCALE
6-,Clle gffAiro41 anio
# ii0/3
INCblUCIILIC11
Temporary Rock Construction Entrance/Exit
X928.5
4.7
1
64 4
1 4.7
-r-
922.8 9234
J._ Aar
"" _
`-Concrete Curb
„Oro: No, 150116 2015 03 12 FE A
X920.5
BEN TON A
*1..c .NLD2.6
!ZIATZIA
10*-0.540%
-15 Initial length
-To front yard setback
line after backfill
itek
.414 •
te.417.
iO4,04114 • 1.0020445,144
2s. VITISTVIA:VA:7.11,.
1-7.7 010.411.10.01P.
ja ASV:: SP.. .12' minimum Non-woven geotextile drainage width
Failure to install the Construction Entrance
before disturbing the site soils and/or failure to
maintain the Construction Entrance will result in
Enforcement action by the City.
6" minimum thickness
11/r to 3" washed rock
fabric under