Loading...
HomeMy WebLinkAbout3211721420038-07012014ER@ Confirm pr perty may be Re • elope priar-te demo on 5, A demor ion permit provides no Assuran of permitted future uses /x 0 905.4 •";\ x 906.4 TC 904.9 X • "NrAP: 46, • II 0) -0 /4 0 X • • TC 905.7 TC x 905.9\ TC 906.1 906.2- Ge 906' • 30(98 909.7 x • • Retaining Vgall NOTE: STORM WATER AND EROSION CONTROL INSPECTIONS SHALL BE COMPLETED ONCE EVERY 7 DAYS OR WITHIN 24 HOURS OF A RAINFALL OF 0.5 INCHES OR GREATER. 902.5 TC 902.9 903.4 TC • ERIST1NG -D,RIVEINAY Open - NI) 9 0 OD' . chi a-- c0 LEGEND PP LP FP EM GM GM 00 - ohe Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Denotes Existing Power Pole Existing Light Pole Existing Flag Pole Existing Electric/Gas Meter Existing Overhead Utility Line(s) Existing Fence Existing Bituminous Surface Existing Concrete Surface Existing Elevation Direction of Drainage Utility Easement, per Final Plat Found Iron Monument Existing Contour Existing Tree, as noted 902. • • I at = 120) 119.86 • 9',(904.0 903 9 N 4' N") CI) 41 - /e--N "". '\ 5 9.\ - Open n n x 9051 Retaining Wall 8.3 /ZZ/z • • • • • • 0 • iINSTALL SILT FENCE (TV) \ / T 1 \ V L_ I \ L_ L_ I INSTALL ROCK CONST. 902.5 ENTR ANCE 2 902.0 TC TC CBTC 903.4 X • 'a EXISTING tONORE,VE DRIVE,W,A 904. X 905.70018 Deck 0.,„0 • 'Coricrete Papa with; Fire it EROSION CONTROL NOTES Silt fence, bio rolls and/or catch basin inlet protection devices shall be installed prior to any land disturbing activity. Rock construction entrances shall be installed prior to any land disturbing activity or after existing driveway is removed. \ HYD TC a?Pinch Top 904.6 • • • ST O R M W A TE R & (.0 01 0 x 909.6 • • • • • • //////24///// 'W//// 4 " x910.7 119.97-z" ==- 120) 4 ft. Chainlink • • 20205 oh. x-91-02101, OE e •--•-• • ' • X 910.2 910.0 • • o2(9215 he 1/7/7719Lit /7/777 L_ / Existing House //. 5805 Tracy Ave. F.F.E.=+914.2 LI-; 911.3 ±30.2 eozo. 14/0,04, L/04 a 4:411%f a")-0, 1414f F0/414 x 0.0 01 • Conditions of Demolition/Moving Ur (-4' construction fencing shall enclose existing basement perimeter and excavations with slopes steeper than 1:1. Attach fencing to minimum posts buried l' and spaced at a maximum 10' on center. 0"/ Enclose stockpiled soils with properly installed silt fencing. ii 2P-roperty must be restored within sixty (60) days of building demolition/move - utilities abandoned at the property line with a permit, foundation demolished with a separate permit, debris removed, demolition excavation filled to match adjacent grade and seed or sod placed and maintained at disturbed areas OR a permit must be issued for a new structure within sixty (60) days of the buildina demolition/move. Any sediment that reaches the existing street or adjacent property shall be removed immediately and measures shall be taken to prevent further sedimentation offsite. 4. All silt fences, bio rolls and catch basin inlet protection devises must be repaired, replaced, or supplemented when they become nonfunctional or the sediment reaches 3S of the height of the device. Repairs shall be made within 24 hours of discovery, or as soon as field conditions allow. INtr.S.Pr..7.r...37ir',....)'NS (7).. h and'AD __Lath Drmsfl insulation Frzlrning and Sheathing • xjatfc_In kiltall Reinforcing apoi Pre,-backfill -igo -T -Ave, 117.aL.sta. 00 n Masonry Fireplace 10 20 40 ( IN FEET ) REVISIONS 6. DRAWN BY: 110 DESIGNED BY: 1:1111 ISSUE DATE: 6/19/14 I hereby certIP, that this plan, specification Or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minneeota Name: Bdan 1. Krystofiak, P.E. SIgnature. bate: 6/19/14 Moose th 25063 1 of 2 TC 908.1 4\ • cr /111 1J52 82a.cm&i, construction entrance must be repaired or sediment and/or excessive sediment is being tracked from the site. Repairs shall be made 77r. and COnartiCtiOn EntranCe within 24 hours of discovery, or as Soon as field conditions allow. DRESS rep aced when the rock becomes inundated with enwwwellie _ AS MANUFACTURED BY ROYAL ENVIRONMENTAL SERVICES INFRASAFE - 2'x3' DEBRIS COLLECTION DEVICE INFRASAFE - 27" DEBRIS COLLECTION DEVICE AS MANUFACTURED BY ROYAL ENVIRONMENTAL SYSTEMS / EMERGENCY OVERFLOW PORTS 2X3 HDPE FRAME INSERT S TO R M W A TE R MA N A G EM E N T D E T A I L S rn 0- 0 REVISIONS S. DRAWN BY: DESIGNED BY: ISSUE DATE: BIb 6/19/14 I hereby certify that this plan, specinottion or report was prepared hy me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws tithe State of Minomom Name: Brian). Krystofialt, P.E. Signature: Date: 6/19/14 License g: 251)63 2 of 2 SILT FENCE ANCHOR W/ METAL T—POST OR WOOD 2"X2" STAKE DIRECTION OF FLOW 5 '117111-1-11 HEHEMEHIEll- • 141111 11C— 1.7-il I 1=1' —'17=-111 1 17— 1 I 6"X6" TRENCH (COMPACTED BACKFILL) FILTER FABRIC (36" MAX. HEIGHT) OPENING IN FABRIC WEAVE < 212 pm UNDISTURBED SOIL SOIL NOTES: 1. DIG A 6"X6" TRENCH ALONG THE INTENDED SILT FENCE LINE. 2. DRIVE ALL ANCHOR POSTS INTO THE GROUND AT THE DOWNHILL SIDE OF THE TRENCH. 3. POSTS SHALL BE SPACED A MAXIMUM OF 6 FEET APART. 4. LAY OUT SILT FENCE ALONG THE UPHILL SIDE OF THE ANCHOR POSTS AND BACK FILL 6"X6" TRENCH. 5. SECURELY ATTACH SILT FENCE TO ANCHOR POSTS W/ MINIMUM OF THREE ATTACHMENTS PER POST. 6. SEE MNDOT SPECIFICATIONS 2573 & 3886. COPOLYMER BARRIER FENCING (48" HEIGHT) ANCHOR W/ METAL T—POST OR WOOD 2"X2" STAKE TREE FENCE fflET Ell II UNDISTURBED SOIL NOTES: 1. TREE FENCING SHALL BE PLACED A MINIMUM OF 1 FOOT PER CALIPER INCH OF TREE DIAMETER FROM TREE(S) THAT IS/ARE TO BE SAVED. 2. ANCHOR POST MAY BE SPACED UP TO 10 FEET APART. 3. SECURELY ATTACH TREE FENCE TO ANCHOR POSTS W/ MINIMUM OF TWO ATTACHMENTS PER POST. 4. SEE MNDOT SPECIFICATION 2572. BIOROLL DETAIL NOTES: 1. ENDS OF BIOROLL SHALL BE A MINIMUM OF 6" HIGHER THAN BOTTOM OF FLOW PATH. 2. STAKES SHALL BE DRIVEN THROUGH THE BACK HALF OF THE BIOROLL. 3. SEE MNDOT SPECS 2573 & 3889. ROCK CONSTRUCTION ENTRANCE riirit*4 ettitetie,da4.7' .;;;„4, 217- 14:;::::77;;;;; "1"44.---"getzok 60. 74-414-.10, V. 0.14/ Oxf kop 40/441 2" CLEAR ROCK (MIN.) 6" MINI. 1"x2" WOODEN STAKE 10" EMBEDMENT DEPTH HDPE INSERT BASKETS SHOWN W/OUT FILTER BAGS 400 MICRON FILTER BAGS REQUIRED INSIDE BASKETS 2'x3' HDPE FRAME INSERT EMERGENCY OVERFLOW PORTS — MEETS MN/DOT SPECIFICATION 3891.F "STORM DRAIN INLET PROTECTION — FILTER BAG INSERT" — DESIGNED FOR NEENAH R-3067 OR R-3290 SERIES HDPE INSERT BASKETS SHOWN W/OUT FILTER BAGS 400 MICRON FILTER BAGS REQUIRED INSIDE BASKETS — MEETS MN/DOT SPECIFICATION 3891.F "STORM DRAIN INLET PROTECTION — FILTER BAG INSERT" — DESIGNED FOR NEENAH R-3250—A OR R-3250-1 (MNDOT 801) FRAME CASTING