HomeMy WebLinkAbout1802824410062-093020152'-6" 5'-0" 1'-0" W CL 5'-0" DETAIL- SHORING AT NEW FNDN. WALL 1/211 = 1'-011 -Ave-, Cgs - STRUCTURAL AV e - NEIGHBORING FOUNDATION APPLIES NO SURCHARGE LOAD TO TEMP. RETAINING WALL. NEW FOUNDATION (SEE PLAN) T-6" AWAY FROM PROPERTY LINE, MIN. 3/4" PLYWOOD OR OSB, (2 -SPAN, MIN.) HSS3x3xl/4" STEEL PILES @ 2'-0" O.C., TYR STRUCTURAL NOTES FOR TEMPORARY RETAINING WALL: 1. BUILD PER THE 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) AND THE 2015 MINNESOTA STATE BUILDING CODE (MSBC) 2. THE EXISTING NET ALLOWABLE BEARING CAPACITY OF THE SOIL IS ASSUMED TO BE 2,000 PSF AND THE EQUIVALENT FLUID PRESSURE IS ASSUMED TO BE 45 PSF/FT, MAX. THE WATER TABLE IS ASSUMED TO BE AT LEAST 10'-0" BELOW BOTTOM OF EXCAVATION CUT. G.C. TO VERIFY. NOTIFY ENGINEER OF ANY POOR SOIL CONDITIONS. 3. SITE DATA WAS TAKEN FROM THE PROPOSED SITE PLAN PROVIDED BY SATHRE-BERGQUIST, INC., DATED SEPTEMBER 8, 2015. 4. FOUNDATION IS ASSUMED TO BE A FULL BASEMENT WITH THE BASE OF THE FOOTING APPROXIMATELY 9'-0" BELOW GRADE. GRADE VARIES ON SITE. 5. SHORING MAY NOT BE REQUIRED IF A GEOTECHNICAL ENGINEER CERTIFIES THAT IT IS NOT NECESSARY (i.e. A MINIMUM OF 1 TO 1 SLOPE IS ACCOMPLISHED WITH NO SURCHARGE LOADING APPLIED ON TOP OF GRADE). 6. LOCATE AND IDENTIFY UTILITIES AND OTHER POSSIBLE OBSTRUCTIONS PRIOR TO INSTALLATION. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF THE EXISTING STRUCTURE, UTILITIES, ETC. DURING CONSTRUCTION. 7. THE STRUCTURE SHALL BE ADEQUATELY BRACED AND SHORED DURING ERECTION AGAINST WIND AND ERECTION LOADS. STRUCTURAL MEMBERS ARE DESIGNED FOR IN-PLACE LOADS. THE ENGINEER DOES NOT CONTROL MEANS AND METHODS OF CONSTRUCTION. 8. THESE DRAWINGSARE PROVIDEDAS CONSTRUCTION DRAWINGS. THE ENGINEER HAS NO CONTROL OVER THE REMOVAL OF THE TEMPORARY RETAINING WALL. 9. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF DISCREPANCIES FOUND BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE CONDITIONS AND DIMENSIONS SHOWN ON THESE DRAWINGS DURING CONSTRUCTION. 10. DO NOT EXCAVATE BELOW THE TEMPORARY RETAINING WALL, ADD SOIL BEHIND THE WALL, DRIVE A VEHICLE NEAR THE TOP OF THE WALL OR APPLY ANY ADDITIONAL SURCHARGE LOAD WITHOUT AUTHORIZATION FROM THE ENGINEER. 11. NOTE THAT THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY 12. PROVIDE CURBS OR OTHER POSITIVE DRAINAGE CONTROLAROUND THE SITE TO PREVENT SURFACE WATER FROM RUNNING INTO THE SITE OR SATURATING THE SOIL BEHIND THE TEMPORARY RETAINING WALL. COVER SLOPES ABOVE THE TEMPORARY WALL WITH POLY -MEMBRANE TO PREVENT SATURATION AND LOSS OF SOIL BEHIND THE WALL. 13. IF CONTRACTOR CAN NO LONGER INSTALL PLYWOOD OR STEEL PLATES IN FRONT OF THE PILES DUE TO POOR SOILS, 2x12 LAGGING MAY BE INSTALLED BEHIND THE PILES. FASTEN WITH A "CONTACT SHEATHING SYSTEM" OR EQUAL. CONTACT ENGINEER FOR MORE INFORMATION. 14. STEEL PILES (Fb = 42 KSI, MIN.), STEEL PLATES (Fb = 36 KSI, MIN.), 3/4" PLYWOOD (40/20 SPAN RATING, MIN.), 2x12 WOOD LAGGING (Fb = 1500 PSI, MIN.) 15. USE OF THESE DRAWINGS IS PROHIBITED FOR OTHER PROJECTS, ADDITIONS TO OR EXTENSIONS OF THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT WITH WRITTEN AUTHORIZATION BY THE ENGINEER. THIS WALL IS TEMPORARY AND SHOULD NOT BE LEFT IN PLACE FOR MORE THAN 30 DAYS. NATE HAVEN STRUCTURAL ENGINEERING www.SafeHavenSE.com MINNEAPOLIS, MN I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the lows of the State of Minnesota. SIGNATURE: PRINTED NAME: Derek 0 Phillips DATE: 09/28/15 REG. NO.: 47507 MARK DATE DESCRIPTION 5132 GORGAS AVENUE EDINA, MN PROJECT NO: 15395 FILE: 15395 SPOING DRAWN BY: DOP DATE: SEPTEMBER 28, 2015 COPYRIGHT: SAFE HAVEN SE SHEET TITLE: SHORING PLAN