HomeMy WebLinkAbout1802824410073-01102014X 888.2
X
888.2
886.8 N89°51 '1 0"E
r/7/7/777777
Existing House V Top of Foundation=
+888.0
3)0 DRAWN By:
1/9/14 ISSUE DATE:
=en o t es
Denotes
Denotes
Denotes
Denotes
Denotes
Denotes
xisting Fence
Existing Bituminous Surface
Existing Concrete Surface
Existing Elevation
Direction of Drainage
Utility Easement, per Final Plat
Found Iron Monument
Existing Contour
Existing Tree, as noted
888.9
26'
8" Tree X 886.8 '--East line of Wes 4-
0
co'
00 L.r)
03
•
-41 prvy 1!!
1-4 / „ t.2:3 _
EROSION CONTROL NOTES
1. Silt fence, bio rolls and/or catch basin inlet
protection devices shall be installed prior to
any land disturbing activity.
I
0
°-#
887.0;1 041
0
887.01 0 N.„e
..^ 4. All silt fences, bio rolls and catch basin inlet
e . AI •. • . 6. > ` f ta: Wood Fence Filence „887.5
---/L-
. protection devises must be repaired, replaced,
or supplemented when they become
I /
/ CALL FO 4 V-Pr; IONIQ 952 826 oqn ..,.., 1;,, • I I lvi ra
N.....
nonfunctional or the sediment reaches )i of the
/887.6 with PERtia NielarMi and ADDRESSf- ' - •
i wi hin 24 hours of discovery, or as soon as
ield conditions allow.
of the device. Repairs shall be made
tracked from the site. Repairs shall be made
ation einforcing within 24 hours of discovery, or as soon as
Pre-backfill field conditions allow.
and Sheathing
AMMER:MYR
_insulation
-Lath
-Drywall
Masonry Fireplace
Final
tO??Lf./ 00 20 40
( IN FEET )
1:2i/57( CIO/ (14(-(f-4x 71tAio()/v4je-
NO TRESPASSING
NO Excavating!
NO Driving!
NO TRESPASSING
on adjoining properties
•
O. 887.3 X ••••••••••••00000••• 42 •0 0••
Conditions of Demolition/Moving
• 4' construction fencing shall enclose existing basement perimeter and
excavations with slopes steeper than 1:1. Attach fencing to minimum
5' posts buried 1' and spaced at a maximum 10' on center.
Enclose stockpiled soils with properly installed silt fencing.
roperty must be restored within thirty (30) days of building
demolition/move - utilities abandoned at the property line with a
permit, foundation demolished with a separate permit, debris
removed, demolition excavation filled to match adjacent grade and
▪ seed or sod placed and maintained at disturbed areas OR a permit
must be issued for a new structure within thirty (30) days of the
building demolition/move.
çL
Pine
_41›,
N89°51'1 0"E
•
--b87 x
itoge italleb r*---. -4"
4 ,/k
Pine
886.7
887.3
• 8 (1.) >
887.3
rt)
87.5
135.00
North line of Lot 56, Aud. Sub. No. 172--i
5 ft. Wood Fe ce 135.00
• • • • • SOS• • • • IS
\ri I 8" Tree 2 1.4
I 887.2 +I 887 1 I +II
to 0 Garage /
SI ab=887.5
'20.6%
Ex:sting /,
887.2 X
• • 0 0 0 • • • X
2. Rock construction entrances shall be installed
prior to any land disturbing activity or after
existing driveway is removed.
3. Any sediment that reaches the existing street
or adjacent property shall be removed
immediately and measures shall be taken to
prevent further sedimentation offsite.
South line of North 66.00 feet Ix
of Lot 56, Aud. Sub. No. 172
(NO SCALE) c„ N o.
.1 5. Rock construction entrance must be repaired or
F-:::1;- Inca ond ,. an ction Entranceeplaced when the rock becomes inundated with
sediment and/or excessive sediment is being pe
IAN 1 0 20;4
DO@
n .0
N,
00
Tree
WORK HOURS: lilt MATERIALS, DUMPSTERS
AND PORTABLE TOILETS 7:00am to 7:00pm Monday through Friday
1-10LIDAys
SHALL NOT BE STORED IN
WORK ON SUNDAY OR
I) 9:00am to 6:00pm Saturday
RIGHT-OF-WAY
SAN. MN. RIM=880.4 INV=870.3 HYD
880.5 IC
r
eN r.
880.1 < d TC
_6
879.8 TC
CD _o
0
(f
879.6
TC
880.4 TC
/ 889.2 TC
fl-S
-
i I
01
I / rR9tK OONST.
I AN.IENTfi CE 887 2 3 3 „ 3
• A, 1
N
I I' \ r \ X
FM- - - - - - - - +41.8
(C (NO SCALE)
1
1
884.2
886.6
/ Concrete 7.1 Driveway
IX885.3 , 886.3
X
X 886.7
1 +42.2-
886.6 X '
18" Ash
//////t3i .Y/////
16" Ash
ee
Confirm p operty may be redeveloped
prior to de olition. A demolition permit
provides no assurance of
uses
itted future
•
fr
VSTALL SILT
FENCE (TIP)
/rE ( (NO SCALE)
1/2 OpenA
\ , .40 ' PP -CO-s , /Denotes
Denotes
388.7 X
Existing Condominium
Top of First Floor Slab=
+889.1
Z/Z/Z/Z/Z/Z/ZZ/
_g/..Z/ZZLZZ/Z/Z fZZ.Zz
&_z/z/z/z2z/zzzA STORM WATER & EROSION CONTROL PLAN (DEMOLITION) (7) >
REVISIONS
z.
s.
DESIGNED BY:
I hereby certify that this plan, specification
or report was prepared by rne or under my direct supervision and that I arn a duly
Licensed Profesional Engineer under the laws 0) 5) State of hilonesola
Name: Brian Krystoliak,
Signature:
Date: 1/9/14 License #: 25063
1
of 3
763-489-795 REVISIONS
2
DRAWN BY: 110
DESIGNED BY: 131K
ISSUE DATE: 1/9/11
1 hereby certify that this plan, specification
or report was prepared Gyms or under my direct supervision and that I am a duly
Licensed Professional Engineer under the
laws of the State of Minnesota
Name: Brian J. Krystofiak, P.E.
SIgnature:4.16/-
Date: 1/9/14 License 5: 25063
EXISTING CONDOMINIUM
4075 51st Street W.
7 1://:_
Top of First Floor Slab=
+889.1
.---7----1-30.1-7- ,
2
of 3
El
Denotes Existing Well
Denotes Existing Electric Meter
Denotes Existing Power Pole
Denotes Existing Overhead Utility Line(s)
Denotes Existing Fence
Denotes Existing Bituminous Surface
Denotes Existing Concrete Surface
Denotes Existing Elevation
Denotes Proposed Elevation
Denotes Direction of Drainage
Denotes Found Iron Monument, as noted
Denotes Set Iron Monument
Denotes Existing Contour
Denotes Proposed Contour
Denotes Existing Hydrant
Denotes Existing Telephone Box
000.0 888.7
X x(001).0)
#72y/i7c---
3-/7/ D0
10 20 40
( IN FEET )
0
LEGEND
-• • •
trio:Y-1-4
Cx:);C) Denotes Proposed Retaining Wall
EROSION CONTROL NOTES
1. Silt fence, bio rolls and/or catch basin inlet
protection devices shall be installed prior to
any land disturbing activity.
2. Rock construction entrances shall be installed
prior to any land disturbing activity or after
existing driveway is removed.
3. Any sediment that reaches the existing street
or adjacent property shall be removed
immediately and measures shall be taken to
prevent further sedimentation offsite.
4. All silt fences, bio rolls and catch basin inlet
protection devises must be repaired, replaced,
or supplemented when they become
nonfunctional or the sediment reaches )5 of the
height of the device. Repairs shall be made
within 24 hours of discovery, or as soon as
field conditions allow.
5. Rock construction entrance must be repaired or
replaced when the rock becomes inundated with
sediment and/or excessive sediment is being
tracked from the site. Repairs shall be made
within 24 hours of discovery, or as soon as
field conditions allow.
L
USE EXIST.--v,
DRWY AS ,
\/CONST.
EN1RANCE
r
r,
- 880.1 o TC
(f)
Li
(.6
0 -J
46 879.8 TC .3)
-e
0
0
879.6 TC
TC 880.4
TC 880.5
880.2
0
IC
0 • • • -4C,A2 • • • I •
co
/ / , IZZZ/Z/ /Z/Z2 .Z_ZZ).A
8866
' INSTALL, ROOK CONST.
ENTRANCE 88-L2
884.2
03
CO
--42.3-
21.83 -42.3-
±7%
; +42.3 - ,
Pine
Match Exist. Wall
CONCRETE
DRIVEWAY
Pine
888.2
X
TW=887.0
,BW=884.0
f? Wood 'Eence N89°5 0"E 135.00
885.9 \--South line of North-..
886.1 885.9 of Lot 56, Aud. Sub. X
Pod /7/7777 -/ 7777/7 -T886.0
'277'
/ A
.40 r0 Yo natiOr
I N
3.0
N89°51'10"E 5 ft Wood Fence 135.00
888.2
26.5 tro. etf l Lri • 6
Raise Found.--/
Wall to 886.0
21 83
„
o ...Aro-0y • .55•5 • • •
EXISTING HOUSE
5105 Halifax Ave.
Top of Foundation=
+888.0
6.83
North line of Lot 56, Aud. Sub. No. 172--
13.5
TW=887.0
BW=884.5.
12.0 0
887.3 tO E/P
14.0
26 Tree
03
V)
▪
Z LLI
0 LLI
0< ▪ C°
o uJ
0_ cc 0 03
0 El_ 0_
20.17tz
Ash
8" Tree
• • • • • • • • S 887.9
9.5
9.5
888.7
TW=887.0 \ -8W=886.0
.00 feet
I o. 172 887.9
./__ZZZZL
073
z
•
• •
888.5
•
•
•
888.9
TALL SILT X 888 2
FENCE (TYP)
Exist. Stone Wall
(to be removed)
x 888.0
888.1
PP
Denotes Existing Trees as noted
Denotes Existing Tree to be Removed
- Denotes Proposed Silt Fence
Denotes Proposed Rock Entrance
„
,
HYD
WELL 0
EM
0
PP
x
BIOROLL DETAIL
FLO Kr 1"x2" WOODEN STAKE 45°
10" EMBEDMENT DEPTH
NOTES:
1. ENDS OF BIOROLL SHALL BE A MINIMUM OF 6" HIGHER THAN BOTTOM OF FLOW PATH.
2. STAKES SHALL BE DRIVEN THROUGH THE BACK HALF OF THE BIOROLL.
3. SEE MNDOT SPECS 2573 & 3889.
ANCHOR W/ METAL
T—POST OR WOOD
2"X2" STAKE
DIRECTION OF FLOW
FILTER FABRIC (36" MAX. HEIGHT)
OPENING IN FABRIC WEAVE < 212 pm
6"X6" TRENCH
(COMPACTED BACKFILL)
11--111-E111.111E111--.
I 7.1-111F—
COPOLYMER BARRIER FENCING
(48" HEIGHT) ANCHOR W/ METAL
T—POST OR WOOD
2"X2" STAKE
7
UNDISTURBED SOIL
HDPE INSERT BASKETS
SHOWN W/OUT FILTER BAGS
•
REQUIRED INSIDE BASKETS
400 MICRON FILTER BAGS
2X3 HDPE FRAME INSERT
z EMERGENCY
OVERFLOW PORTS
44114,1k,
ife-fgeeter,,c.,
._41,44g04,11_
ftittriatiM‘o•JOV/4,t4
•-•••illk,11-4,-*-dkOzet
6-071.4*:".0:947
4-Arto r
2" CLEAR
ROCK (MIN.)
6" MIN.
I hereby certify that this plan, specification or report was prepared by me or under my
direct supervision and that I are a duly Licensed Professional Engineer under the
laws of the State of Minnesota
Name: Brian J. Krystofiak, P.E.
Signature:
Date: 1/9/14 Usense rt: 25063 LAW. subrAvIslon 0 Lr) 2
SILT FENCE
UNDISTURBED SOIL
NOTES:
1. DIG A 6"X6" TRENCH ALONG THE INTENDED SILT FENCE LINE.
2. DRIVE ALL ANCHOR POSTS INTO THE GROUND AT THE DOWNHILL SIDE OF THE TRENCH.
3. POSTS SHALL BE SPACED A MAXIMUM OF 6 FEET APART.
4. LAY OUT SILT FENCE ALONG THE UPHILL SIDE OF THE ANCHOR POSTS AND BACK FILL 6"X6" TRENCH.
5. SECURELY ATTACH SILT FENCE TO ANCHOR POSTS W/ MINIMUM OF THREE ATTACHMENTS PER POST.
6. SEE MNDOT SPECIFICATIONS 2573 & 3886.
TREE FENCE
NOTES:
1. TREE FENCING SHALL BE PLACED A MINIMUM OF 1 FOOT PER CALIPER INCH OF TREE DIAMETER
FROM TREE(S) THAT IS/ARE TO BE SAVED.
2. ANCHOR POST MAY BE SPACED UP TO 10 FEET APART.
3. SECURELY ATTACH TREE FENCE TO ANCHOR POS TS W/ MINIMUM OF TWO ATTACHMENTS PER POST.
4. SEE MNDOT SPECIFICATION 2572. STORMWATER MANAGEMENT DETAILS INFRASAFE — 2'x3' DEBRIS COLLECTION DEVICE
AS MANUFACTURED BY ROYAL ENVIRONMENTAL SYSTEMS
2'x3 HDPE FRAME INSERT
EMERGENCY
OVERFLOW PORTS
— MEETS MN/DOT SPECIFICATION 3891.F
"STORM DRAIN INLET PROTECTION — FILTER BAG INSERT"
— DESIGNED FOR NEENAH R-3067 OR R-3290 SERIES
INFRASAFE — 27" DEBRIS COLLECTION DEVICE
AS MANUFACTURED BY ROYAL ENVIRONMENTAL SERVICES
— MEETS MN/DOT SPECIFICATION 3891.F
"STORM DRAIN INLET PROTECTION — FILTER BAG INSERT"
— DESIGNED FOR NEENAH R-3250—A OR R-3250-1 (MNDOT 801)
FRAME CASTING
ROCK CONSTRUCTION ENTRANCE
JAN 10 MJ
f6lc7 /7f7
372/ hie(im)c
HDPE INSERT BASKETS
SHOWN W/OUT FILTER BAGS
400 MICRON FILTER BAGS
REQUIRED INSIDE BASKETS
REVISIONS
DRAWN BY: J3D
DESIGNED BY: EUK
ISSUE DATE: 1/9/14