HomeMy WebLinkAbout1902824430037-11122013000.00
( Nom )
•
Denotes found iron pipe
Denotes existing elevation
Denotes proposed devotion
Denotes drainage flow direction
Denotes spike
Denotes utility pole
Denotes fence (wood)
Denotes fence (chain link)
Denotes underground gas line
885.1
885.2
885.1
0
0
tu.1
-7
Garage • . •
/ 889.4
/ 888.7 LI
(889.3)
(888.9)
(889.5)
(888.5)
Top Of Foundation Elev.
Garage Slab Elev. CO Door
Proposed 1st Floor Elevation
Existing 1st Floor Elevation
v.3; .cat .S015-1
1vO Psetv%
BY:
Lot 8, Block 20, FAIRFAX ADDITION
according to the recorded plat thereof Hennepin County, Minnesota
Address: 6028 Kellogg Avenue, Edina, Minnesota
House Model: Custom Elevation: n/a
Buyer: Spec
Scale: 1" = 20'
Denotes tree
Denotes proposed retaining walls Immo designed and built by others.
887.4
7.
• ,• • , •A el • 886.2° 88645
-41
5.0
885.
885.2
886.5 886.6 886.7
886 86.4 886.5 886. (886.6) .5 132.40 b
tw=887.0
bw=856.5
X $86.7
885.
----- - 34.6 ---
886.7 886.6
886. 886
88.
58.213 X 886.3
L 885.6
We hereby certify to Brandi Anderson Homes
plan or report was prepared by me or under
and that I am a duly licensed Land Surveyor
the State of Minnesota, dated 05/28/13.
Signed: Pi neer ngineering, P.A.
:4
ail-phawkinson@pioneereng.com
X 88"
(866.7)
Peter J. Hawkinson, Professional Land Surveyor
Minnesota License No. 42299
Lfi 2..sit, \(.12 ‘1!). 11.).1r1
-oe3037
• 0'86,2)• °
886.4
883,46 lstflp
886.2.
Existing
House
566.1 -§esi
• X881 X 055.4 884.7
--- 34.7 - ----- 88
884.9
E84.8
8 5
X 686.5 886.2
885.4 X 885.9
BOLDING DEPARTRENT
'11.011
1 2 2013
CITOP 01414
30
LLJ
LJ
Lot area = 6620 SF
Proposed House area =1845 SF
Proposed Porch area = 146 SF
Impervious Coverage =30.0 %
Construction Notes:
1. Install rock construction entrance.
2. Install silt fence as needed for erosion control.
3. Sidewalks shall drain away from house a minimum of 1.0%.
4. Contractor must verify driveway design.
5. Contractor must verify service elevation prior to construction.
6. Add or remove foundation ledge as required.
General Notes:
1. Grading plan by n/a last dated n/a was used to determine proposed
elevations shown herein.
2. This survey does not purport to show improvements or
encroachments, except as shown, as surveyed by me or under my
direct supervision.
3. Proposed building dimensions shown are for horizontal location of
structures on the lot only. Contact builder prior to construction for
approved construction plans.
4. No specific soils investigation has been performed on this lot by the
surveyor. The suitability of soils to support the specific house proposed
is not the responsibility of the surveyor.
5. This certificate does not purport to show easements other than
those shown on the recorded plat.
6. Bearings shown are based on an assumed datum.
30
Inc that this survey,
my direct supervision
under the laws of
886.8
Existing
/ House
X 886.8
888.3 #
REVISED 11/08/13 FOUNDATION AS-BUILT
House elevations (Proposed) / As-built
Lowest Floor Elevation :(879.6) / 879.4 FTG