HomeMy WebLinkAbout(110) Tracer Wire Access BoxCOMPLETE BOX SIDE VIEW
N
CAP SHALL BE BURIED
FINISH GRADE — /-2-3" BELOW FINAL GRADE
Al A f
O N
M
wIR�
LID TOP VIEW
STAINLESS STEEL
TERMINAL BOLTS
LID SIDE VIEW
CONCRETE BRICK �ug
2' #6 REBAR
LOCATED ALONGSIDE
ACCESS BOX
4.0"
DRIVE—IN MAGNESIUM COLLAR VIEW TOP
GROUNDING ANODE ROD
TRACER WIRE ACCESS BOX SHALL BE A DRAINAGE & WATER
SOLUTIONS MODEL #TRWAB OR APPROVED EQUAL. BOXES
CONSTRUCTED IN PAVED AREAS REQUIRE THE INSTALLATION
OF A FORD TYPE A SINGLE LID COVER OR APPROVED EQUAL.
LEAVE A MINIMUM OF 2' OF TRACER WIRE SLACK IN BOX.
TRACER WIRE ACCESS BOX SHALL BE PAINTED BY THE
CONTRACTOR IN THE FIELD WITH ENAMEL PAINT IN THE
CORRESPONDING COLOR
• WATER = BLUE
• STORM SEWER/SUMP/SANITARY = GREEN
• ELECTRICAL = RED
• COMMUNICATION = ORANGE
• GAS = YELLOW
NOTES:
CASTING MUST CONFORM TO:
ASTM SPECIFICATION A-48 CLASS 30
COUNTRY OF ORIGIN: USA
ABS SHAFT MUST CONFORM TO:
ASTM SPECIFICATIONS D-1788
COUNTRY OF ORIGIN: USA
NA.M� CITY OF EDINA REVISED:
ENGINEERING TRACER WIRE ACCESS BOX 01-16
o &PUBLIC STANDARD
�\ WORKS
"`�aca DEPTS. APPROVED: CITY ENGINEER 1 1 0