HomeMy WebLinkAbout(120) Concrete Thrust Block-e--SEE NOTE 2 CONCRETE SHALL BE IN CONTACT WITH THIS QUADRANT OF PIPE PLAN BEDDING MATERIAL go• BENDS PLACE PLASTIC SHEETING AGAINST PIPE AS SHOWN CONCRETE APPROXIMATE 1:1 SLOPE WHERE DEPTH BELOW PIPE EXCEEDS 6". SECTION A-A BUTTRESS DIMENSIONS PIPE 22 1/2' BEND 45' BEND SIZE B 1 D 1 B2 D2 6" 1'-5" 1'-5" 1'-5" 1'-5" 8" 1'-5" 1'-5" 2'-1" 1'-6" 12" 1'-10" 1'-10" 3'-4" 2'-0" 16" 3'-0" 2'-0" 3'-10" 3'-0" 20• 3'-6" 2'-8" 5'-6" 3'-4" 24" 4'-4" 3'-0" 6'-10" 3'-10" 1 TEES/90' BEND B3 D3 2·-1· 1'-6" 2'-8" 2'-0" 4'-9" 2'-6" 6'-2" 3'-6" 8'-4" 4'-0" 9'-8" 5'-0" 11=1 =rn-- 'TJ=-T'""" PLAN -22 1 /2·-45· BENDS PLAN -45· BENDS NOTES: 1. DIMENSIONS IN TABLE ARE BASED ON A WATER PRESSURE OF 150 PSI AND AN EARTH RESISTANCE OF 1 TON PER SQ. FT. 2. DIMENSION C1,C2,C3 SHOULD BE AS LARGE ENOUGH TO MAKE ANGLE > 45 DEGREES. 3. DIMENSION A1,A2,A3 SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERING WITH M.J. BOLTS. 4. SHAPE OF BACK OF BUTTRESS MAY VARY AS LONG AS POUR IS AGAINST FlRM UNDISTURBED EARTH. 5. MEGA LUGS MAY BE USED IN CONJUNCTION WITH MIXED CONCRETE THRUST BLOCKING. 6. READY MIX CONCRETE ONLY MAY BE USED (MNDOT SPEC. 2461, GRADE 'B') CITY OF EDINA ENGINEERING & PUBLIC WORKS DEPTS. CONCRETE THRUST BLOCK REVISED: 04-09 APPROVED: CITY ENGINEER STANDARD PLATE 120