HomeMy WebLinkAbout(240) Flared End SectionTIE LAST 3 PIPE JOINTS. USE 2 TIE
BOLT FASTENERS PER JOINT INSTALLED
AT 60 DEGREES FROM TOP OF PIPE.
PROVIDE 3 CUPS TO FASTEN TRASH GUARD TO
FLARED END. HOT DIP GALVANIZE AFTER FABRICATION.
RIPRAP AS SPECIFlED IN MnDOT
STANDARD SPECS. 2511.3 AND 3601.2.
RIP RAP QUANTITY SHALL BE
IN ACCORDANCE WITH MnDOT STD. PLT. 3133
NOTES: TRASH GUARDS TO BE INSTALLED ON 18" OR LARGER SIZED INLETS.
TRASH GUARDS MAY BE INSTALLED ON OUTLETS AT THE
DISCRETION OF THE ENGINEER.
BOLT
"H" SIZE
ANCHOR BOTH SIDES
UNDER FULL LENGTH
OF FLARED END SECTION
SAND FlLTER
BLANKET
FlLTER FABRIC
PLAN VIEW
FlLTER FABRIC
SECTION A-A
SECTION 8-8
FLARED END SECTION
REVISED:
01-17
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
1--~~~~~~~....--,..~~~__,,1<--~~~~~~~~-----i STANDARD
PLATE
APPROVED: CITY ENGINEER 240