HomeMy WebLinkAbout(300) Sewer and Water Service ConnectiontfQIES:_
ANY CURB STOP LOCATED IN BLACKTOP OR CONCRETE DRIVEWAY
OR SIDEWALK SHALL BE COVERED WITH METER BOX COVER
(FORD A-1) OR APPROVED EQUAL
ALL WATER SERVICES SHALL BE 1" MIN., TYPE K COPPER, AND
SHALL USE A SMITH BLAIR STAINLESS STEEL SADDLE TYPE f/317 OR
#372, OR APPROVED EQUAL
WATER SERVICE MUST BE CONTINUOUS WITH NO JOINTS UNLESS
SERVICE IS OVER 100' LONG.
SANITARY AND WATER SERVICE LINES SHALL BE INSTALLED IN THE
SAME TRENCH WITH 3' OF SEPARATION.
EXCESSIVE SANITARY SEWER MAIN-LINE DEPTH SHALL BE REVIEWED
AND APPROVED BY THE ENGINEER.
VARIES (SEE PLAN)
VARIES (SEE PLAN) ADJUST CURBSTOP TO 1"
BELOW FINISHED GRADE
CURB BOX SHALL BE MUELLER
H-10300 MINNEAPOLIS PATTERN
1 1/4" STACK FOR USE WITH 1"
CURB STOP.
1" CURB STOP SHALL BE
MUELLER H-15154 MINNEAPOLIS
PATTERN OR APPROVED EQUAL
ALL STOPS SHALL BE
FLARED FOR BOTH INLET & OUTLET.
WATER MAIN
CORPORATION STOP SHALL BE
MUELLER H-15000 OR APPROVED
EQUAL WITH MUELLER THREAD
FLARE TYPE JOINT.
WATER SERVICE
CONCRETE BRICK
1'
4" OR 6" PVC SDR 26 SEWER SERVICE I
PIPE. MIN SLOPE 1/4" PER FT. (2.0%)_/
12"
REVISED:
01-17
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
1--~~~~~~~-=;...-=-;.....:....:c_:..::=-..;::;..._;:_.;.....;;;.....:......;;..__~~~~~~----1STANDARD
PLATE
APPROVED: CITY ENGINEER 300