HomeMy WebLinkAbout(301) Sewer and Water Service Connection with RiserVARIES (SEE PLAN) VARIES (SEE PLAN) STEEL FENCE POST J 7.5' MIN. CURB BOX SHALL BE MUELLER H-10300 MINNEAPOLIS PATTERN 1 1/4" STACK FOR USE WITH 1" CURB STOP. 1" CURB STOP SHALL BE MUELLER H-15154 MINNEAPOLIS PATTERN OR APPROVED EQUAL ALL STOPS SHALL BE FLARED FOR BOTH INLET & OUTLET. I 1' l ~ 2"x2" .... MARKER t Ffn ~ 0:: LI.I 0.. !!;; 0.. LI.I:::> 0 c8 0:: 0.. :Z 0:: WATER MAIN_/ WATER SERVICE CONCRETE BRICK CORPORATION STOP SHALL BE MUELLER H-15000 OR APPROVED EQUAL WITH MUELLER THREAD FLARE TYPE JOINT. !$! -Ul ::::ii< 0:: LI.I bo:: Ul T'""Q ~ CITY OF EDINA ENGINEERING & PUBLIC WORKS DEPTS. MIN SLOPE 1/4" PER FT. (2.0%) STUB ELEV. 4" OR 6" PVC SOR 26 SEWER SERVICE PIPE. SANITARY SERVICE WYE TURNED UP AT A 45' SANITARY SEWER MQIE.S.:_ ANY CURB STOP LOCATED IN BLACKTOP OR CONCRETE DRIVEWAY OR SIDEWALK SHALL BE COVERED WITH METER BOX COVER (FORD A-1) OR APPROVED EQUAL ALL WATER SERVICES SHALL BE 1" MIN., TYPE K COPPER, AND SHALL USE A SMITH BLAIR STAINLESS STEEL SADDLE TYPE #317 OR #372, OR APPROVED EQUAL WATER SERVICE MUST BE CONTINUOUS WITH NO JOINTS UNLESS SERVICE IS OVER 100' LONG. SANITARY AND WATER SERVICE LINES SHALL BE INSTALLED IN THE SAME TRENCH WITH 3' OF SEPARATION. EXCESSIVE SANITARY SEWER MAIN-LINE DEPTH SHALL BE REVIEWED AND APPROVED BY THE ENGINEER. SANITARY SEWER SERVICE RISER SHALL BE BACKFILLED WITH GRANULAR MATERIAL AND COMPACTED. SEWER AND WATER SERVICE REVISED: 01-17 APPROVED: CITY ENGINEER