HomeMy WebLinkAbout(310) Sump DrainEXISTING GRADE lll.QlESL SUMP DRAIN PIPE SHALL BE SECURELY SET INTO EXISTING CATCH BASINS OR MANHOLES USING GROUT OR APPROVED PIPE SEALS SO THAT S1RUCTURE IS WATERTIGHT. RODENT GUARDS SHALL BE INSTALLED AT EACH OF THESE CONNECTIONS. INSTALL CLEANOUTS AT 300 FOOT INTERVALS (MAX.) TEES, AND ENDS OF LINES. CON1RACTOR SHALL PROVIDE CITY 'MTH SURVEY QUALITY XVZ LOCATES OF CLEANOUTS FOR UTILITY ASBUILT RECORDS. ELEVATION VIEW ALL PVC CLEANOUTS SHALL BE 3" -6" BELOW FINISHED GRADE AND HAVE A THREADED PLUG FITTING (SCHEDULE 40). (TYP.) 1RACER 'MRE END OF LINE~ 90' RADIUS BEND ~ 6" PVC/HOPE SUMP DRAIN PIPE CROSS SECTION VIEW EXISTING GRADE ~ . i~ ... •· . . 4:f • • d • . ., • 4. 3' OR SERVICE TEES SHALL BE r--1.5' DIR:6'TED INSTALLED AT THE DIRECTION~! (MIN.) BY THE OF THE ENGINEER. ':I-ENGINEER Lt_=li~ j 4• PVC SDR 35 OR-r~e• SUMP ORAIN PIPE 4• PVC C900 (HOPE SOR 17, PVC SOR 35, OR PVC C900) SUMP DRAIN 1RACER 'MRE ACCESS BOX (EDINA STANDARD PLATE 110) 1RACER 'MRE SHALL RUN THE FULL LENGTH OF CLEANOUT AND BE INSTALLED IN A 1RACER 'MRE ACCESS BOX PER EDINA STANDARD PLATE 110 (TYP.) *NOT TO SCALE* CURB & GUTTER lll.QlESL CONNECTIONS TO SUMP DRAIN PIPE SHALL BE MADE 'MTH A FERNO BRAND FLEXIBLE SADDLE TEE/WYE, A PVC TEE/WYE, OR APPROVED EQUAL CON1RACTOR SHALL PROVIDE CITY 'MTH SURVEY QUALITY XVZ LOCATES OF SERVICE TEES FOR UTILITY ASBUIL T RECORDS. *NOT TO SCALE* REVISED: 01-17 CITY OF EDINA ENGINEERING & PUBLIC WORKS DEPTS. 1--~~~~~~---..,.,,....,..~~~~~.,....-~~~~~~~--1 STANDARD PLATE APPROVED: CITY ENGINEER 310