HomeMy WebLinkAbout(310) Sump DrainEXISTING GRADE
lll.QlESL
SUMP DRAIN PIPE SHALL BE
SECURELY SET INTO EXISTING
CATCH BASINS OR MANHOLES
USING GROUT OR APPROVED
PIPE SEALS SO THAT
S1RUCTURE IS WATERTIGHT.
RODENT GUARDS SHALL BE
INSTALLED AT EACH OF THESE
CONNECTIONS.
INSTALL CLEANOUTS AT 300
FOOT INTERVALS (MAX.) TEES,
AND ENDS OF LINES.
CON1RACTOR SHALL PROVIDE
CITY 'MTH SURVEY QUALITY XVZ
LOCATES OF CLEANOUTS FOR
UTILITY ASBUILT RECORDS.
ELEVATION VIEW
ALL PVC CLEANOUTS SHALL BE
3" -6" BELOW FINISHED GRADE
AND HAVE A THREADED PLUG
FITTING (SCHEDULE 40). (TYP.)
1RACER 'MRE
END OF LINE~
90' RADIUS BEND ~
6" PVC/HOPE SUMP DRAIN PIPE
CROSS SECTION VIEW
EXISTING GRADE
~ . i~ ... •· . . 4:f •
• d •
. ., • 4.
3' OR
SERVICE TEES SHALL BE r--1.5' DIR:6'TED
INSTALLED AT THE DIRECTION~! (MIN.) BY THE
OF THE ENGINEER. ':I-ENGINEER
Lt_=li~ j
4• PVC SDR 35 OR-r~e• SUMP ORAIN PIPE
4• PVC C900 (HOPE SOR 17,
PVC SOR 35, OR
PVC C900)
SUMP DRAIN
1RACER 'MRE
ACCESS BOX
(EDINA STANDARD
PLATE 110)
1RACER 'MRE SHALL
RUN THE FULL
LENGTH OF CLEANOUT
AND BE INSTALLED IN
A 1RACER 'MRE
ACCESS BOX PER
EDINA STANDARD
PLATE 110 (TYP.)
*NOT TO SCALE*
CURB & GUTTER
lll.QlESL
CONNECTIONS TO SUMP
DRAIN PIPE SHALL BE MADE
'MTH A FERNO BRAND
FLEXIBLE SADDLE TEE/WYE, A
PVC TEE/WYE, OR APPROVED
EQUAL
CON1RACTOR SHALL PROVIDE
CITY 'MTH SURVEY QUALITY
XVZ LOCATES OF SERVICE
TEES FOR UTILITY ASBUIL T
RECORDS.
*NOT TO SCALE*
REVISED:
01-17
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
1--~~~~~~---..,.,,....,..~~~~~.,....-~~~~~~~--1 STANDARD
PLATE
APPROVED: CITY ENGINEER 310