HomeMy WebLinkAbout2021-096 Grading and Drainage PlanPROPOSED MULTIFAMILY BUILDING 118 UNITS FFE: 872.50 P1 FFE: 860.50VALLEY VIEW ROAD70TH STREET WEST 87587587187187287287387387487487 0 867868869866867868869870870870870869869 8698708698 6 9 869871870868 869871868 8 6 9 870 870 871871D DD D DD D 8688688658648648664 LF - 15" @ 0.00% 35 LF - 15" @ 0.46% 79 LF - 15" @ 0.50% 40 LF - 15" @ 0.50% 29 LF - 12" @ 0.75% 11 LF - 12" @ 2.50% 33 LF - 12" @ 3.00% 31 LF - 15" @ 0.65% 96 LF - 12" @ 0.70% 33 LF - 15" @ 0.95% 9 LF - 18" @ 1.33% 1.79%2.74% 2.22% 3.93% 5.46 %5.4 6% 5.63% 5. 52 % 1.34% 5.22% 9.1 4%2.45%26.12%33.33%3:19:1 5.51% 3.86% 1.78%28.15%25.00%3. 9 1 % 21.23% 18.66% 23.97% 1.80% 1 .8 4% 1.98% 1.70%1.60%1.90%4.91% 4.9 9 % 4.95 %11.65%5.19%10.28%3.81%5.13% 4. 9 4%8.46% 2.13% 9.71%9.72% 9.67%9.72% 8.2 8 % 9.71% 1. 75 %2.96%1.81%13.36%11. 9 3 % 1. 1 4% 1.06 %2 . 5 4%2.0 1% 0 .79%0.80%0.41%0. 9 5% 0. 9 6%0.99%1.23 %2.53% 1 .80%1.31%1.90%2.30% 60" CHAMBER INFILT. SYSTEM BOTTOM OF CHAMBER: 861.25 100-YEAR HWL: 865.85 5:1 7:1 7.8 6 % DD LIFT STATION DESIGN BY OTHERS. EXPECTED FLOW RATE = 1.21 CFS RIM: 871.13 4.78%30.84% 33.33% 1 9.66 % 33.33%33.33% 1.01 %1.58%1.53 % 5 :14" PERFORATED PVC DRAINTILE IE: 865.00 TWO 4" PERFORATED PVC DRAINTILE IE: 861.85 CO PROPOSED RAIN GARDEN BOTTOM: 863.85 ENGINEERED SOIL MEDIA/DRAINTILE IE: 861.85 100-YEAR HWL: 865.42 5:1 4:1 PROPOSED RAIN GARDEN BOTTOM: 867.00 ENGINEERED SOIL MEDIA/DRAINTILE IE: 865.00 100-YEAR HWL: 869.84 74 LF - 12" @ 2.50% G:860.50 G:860.41 G:867.67G:867.23 G:866.19 G:866.50 G:867.48 G:867.68 G:867.85 G:867.68 T/G:872.26 T/G:872.19 T/G:872.00 T/G:872.10 G:871.89G:869.65 G:868.30 G:869.10 G:869.04 G:868.91 TW:873.79 BW:860.63 TW:872.50 BW:872.50 G:870.59 G:871.53 G:871.62 G:870.58 G:871.29 G:871.28 G:870.98 G:866.87 G:867.19 T/G:866.47 G:868.84 G:868.55 G:868.41 ME:867.38 ME:865.48 872.50 872.38 872.50 872.50 872.49 872.26 872.50 872.44 872.50 872.50 870.50 872.50 872.50 872.50 868.18 TS:872.44 865.48 870.50 872.50872.50872.48 ME:865.34 ME:864.89 ME:869.06 ME:869.32 ME:870.06 ME:870.04 872.36 872.10 872.46 872.35 869.39 870.25 870.12 870.08 869.48 869.42 868.64 ME:869.07 ME:868.02 868.42 872.48 872.47 872.50 872.29 869.36 869.30 868.09 867.75 867.73 867.62 870.34 870.16 HP:868.60 872.50 T/G:872.07 T/G:871.77 TW:871.00 BW:868.61 HP:868.60 BS:869.39 869.31 868.60 868.70 G:867.70 G:867.68 T/G:867.54T/G:867.38 TS:872.44 872.48 872.50 872.50 TW:872.50 BW:868.72 TW:872.50 BW:868.71 TW:872.50 BW:872.50 TW:872.50 BW:871.45 872.19 870.96 870.95 868.77 868.70 T/G:872.33 872.27 872.41 871.30 871.39 871.42 870.47 870.43 872.50 872.50 872.00 872.50 872.50 869.46 869.40 869.72 869.66 G:868.09 TW:872.64 BW:871.27 TW:872.64 BW:864.67 TW:874.00 BW:860.50 ST-16 RE:870.00 IE:862.87 N ST-18 RE:868.91 IE:864.00 E ST-19 RE:868.79 IE:863.62 NW IE:863.86 E IE:863.52 SST-3 RE:868.64 IE:862.22 S IE:862.22 NW ST-5 RE:867.89 IE:862.06 SE IE:862.20 S IE:861.96 NE ST-8 RE:867.68 IE:863.84 SE ST-12 IE:869.20 N ST-11 IE:869.00 W ST-7 RE:864.91 IE:861.26 SW IE:861.17 N ST-1 IE:860.97 S ST-15 RE:865.42 IE:861.57 SW IE:861.47 NE ST-13 RE:870.96 IE:867.27 SE ST-2 IE:862.22 N ST-20 RE:868.93 IE:863.40 N ST-21 RE:870.11 IE:863.68 W ST-22 CONNECT TO TRENCH DRAIN IE:858.80 SW 32 LF - 12" @ 3.00% ST-26 IE:868.22 S IE:868.22 NW 872.50 TW:868.25 BW:867.24 BS:869.39 1.93% 871.97 871.96 NORTH GRADING PLAN NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF EDINA, SPECIFICATIONS AND BUILDING PERMIT REQUIREMENTS. 2. CONTRACTOR TO CALL GOPHER STATE CALL ONE @ <1-800-252-1166> AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION/CONSTRUCTION FOR UTILITY LOCATIONS. 3. STORM SEWER PIPE SHALL BE AS FOLLOWS: RCP PER ASTM C-76 HDPE: 0" - 10" PER AASHTO M-252 HDPE: 12" OR GREATER PER ASTM F-2306 PVC SCH. 40 PER ASTM D-1785 STORM SEWER FITTINGS SHALL BE AS FOLLOWS: RCP PER ASTM C-76, JOINTS PER ASTM C-361, C-990, AND C-443 HDPE PER ASTM 3212 PVC PER ASTM D-3034, JOINTS PER ASTM D-3212 4. CONTRACTOR TO FIELD VERIFY THE LOCATIONS AND ELEVATIONS OR EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO THE START OF SITE GRADING. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES OR VARIATIONS. 5. SUBGRADE EXCAVATION SHALL BE BACKFILLED IMMEDIATELY AFTER EXCAVATION TO HELP OFFSET ANY STABILITY PROBLEMS DUE TO WATER SEEPAGE OR STEEP SLOPES. WHEN PLACING NEW SURFACE MATERIAL ADJACENT TO EXISTING PAVEMENT, THE EXCAVATION SHALL BE BACKFILLED PROMPTLY TO AVOID UNDERMINING OF EXISTING PAVEMENT. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL. 7. CONTRACTOR SHALL EXCAVATE DRAINAGE TRENCHES TO FOLLOW PROPOSED STORM SEWER ALIGNMENTS. 8. GRADES SHOWN ARE FINISHED GRADES. CONTRACTOR SHALL ROUGH GRADE TO SUBGRADE ELEVATION AND LEAVE STREET READY FOR SUBBASE. 9. ALL EXCESS MATERIAL, BITUMINOUS SURFACING, CONCRETE ITEMS, ANY ABANDONED UTILITY ITEMS, AND OTHER UNSTABLE MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF THE CONSTRUCTION SITE. 10. REFER TO THE UTILITY PLAN FOR SANITARY SEWER MAIN, WATER MAIN SERVICE LAYOUT AND ELEVATIONS AND CASTING / STRUCTURE NOTATION. 11. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF PAVEMENTS AND CURB AND GUTTER WITH SMOOTH UNIFORM SLOPES TO PROVIDE POSITIVE DRAINAGE. 12. INSTALL A MINIMUM OF <4" CLASS 5> AGGREGATE BASE UNDER CURB AND GUTTER AND CONCRETE SIDEWALKS. 13. UPON COMPLETION OF EXCAVATION AND FILLING, CONTRACTOR SHALL RESTORE ALL STREETS AND DISTURBED AREAS ON SITE. ALL DISTURBED AREAS SHALL BE RE-VEGETATED WITH A MINIMUM OF <4" OF TOPSOIL>. 14. ALL SPOT ELEVATIONS/CONTOURS ARE TO GUTTER / FLOW LINE UNLESS OTHERWISE NOTED. 15. GRADING FOR ALL SIDEWALKS AND ACCESSIBLE ROUTES INCLUDING CROSSING DRIVEWAYS SHALL CONFORM TO CURRENT ADA STATE/NATIONAL STANDARDS. IN NO CASE SHALL ACCESSIBLE RAMP SLOPES EXCEED 1 VERTICAL TO 12 HORIZONTAL. IN NO CASE SHALL SIDEWALK CROSS SLOPES EXCEED 2% . IN NO CASE SHALL LONGITUDINAL SIDEWALK SLOPES EXCEED 5%. IN NO CASE SHALL ACCESSIBLE PARKING STALLS OR AISLES EXCEED 2% (1.5% TARGET) IN ALL DIRECTIONS. SIDEWALK ACCESS TO EXTERNAL BUILDING DOORS AND GATES SHALL BE ADA COMPLIANT. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ADA CRITERIA CANNOT BE MET IN ANY LOCATION PRIOR TO PAVING. NO CONTRACTOR CHANGE ORDERS WILL BE ACCEPTED FOR A.D.A COMPLIANCE ISSUES. 16. MAINTAIN A MINIMUM OF 0.5% GUTTER SLOPE TOWARDS LOW POINTS. 17. CONTRACTOR TO PROVIDE 3" INSULATION BY 5' WIDE CENTERED ON STORM PIPE IF LESS THAN 4' OF COVER IN PAVEMENT AREAS AND LESS THAN 3' OF COVER IN LANDSCAPE AREAS. 18. ROOF DRAIN INVERT CONNECTIONS AT THE BUILDING SHALL BE AT ELEVATION <XXX.XX> OR LOWER UNLESS NOTED OTHERWISE. REFERENCE MEP PLANS FOR ROOF DRAIN CONNECTION. 19. ALL STORM SEWER CONNECTIONS SHALL BE GASKETED AND WATER TIGHT INCLUDING MANHOLE CONNECTIONS. 20. ALL STORM SEWER PIPE SHALL BE AIR TESTED IN ACCORDANCE WITH THE CURRENT PLUMBING CODE. 21. MAINTAIN A MINIMUM OF 1.25% SLOPE IN BITUMINOUS PAVEMENT AREAS, 0.5% SLOPE IN CONCRETE PAVEMENT AREAS. 22. CONTRACTOR SHALL REVIEW PAVEMENT GRADIENT AND CONSTRUCT "INFALL CURB" WHERE PAVEMENT DRAINS TOWARD GUTTER, AND "OUTFALL" CURB WHERE PAVEMENT DRAINS AWAY FROM GUTTER. 23. CONTRACTOR SHALL NOTIFY PROJECT ENGINEER A MINIMUM OF 3 DAYS PRIOR TO UNDERGROUND STORMWATER INSTALLATION FOR THIRD PARTY OBSERVATION (PER CITY OF EDINA REQUIREMENTS) PROPOSED STORM SEWER PROPOSED STORM SEWER PROPERTY LINE EXISTING CONTOUR PROPOSED CONTOUR925 PROPOSED SPOT ELEVATION100.00 LEGEND PROPOSED HIGH POINT ELEVATIONHP:0.0 PROPOSED LOW POINT ELEVATION PROPOSED GUTTER ELEVATION PROPOSED TOP OF CURB ELEVATION PROPOSED FLUSH PAVEMENT ELEVATION LP:0.0 G:0.00 T:0.00 PROPOSED EMERGENCY OVERFLOW T/G:0.0 EOF:0.0 0.0%PROPOSED DRAINAGE DIRECTION 0.00%PROPOSED ADA SLOPE ME:0.0 MATCH EXISTING ELEVATION PROPOSED STORM MANHOLE (SOLID CASTING) PROPOSED STORM MANHOLE (ROUND INLET CASTING) PROPOSED STORM MANHOLE/ CATCH BASIN (CURB INLET CASTING) PROPOSED STORM SEWER CLENOUT PROPOSED RIPRAP PROPOSED FLARED END SECTION CO D BYREVISIONSNo.DATESHEET NUMBER©K:\TWC_LDEV\LUPE DEVELOPMENT\Edina Multifamily\3 Design\CAD\PlanSheets\C5-GRADING PLAN.dwg June 08, 2022 - 1:40pmDATECHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT16006200106/08/2022AS SHOWNDSSDSSBMWPREPARED FORGRADING ANDDRAINAGE PLANC500EDINA MULTIFAMILYLUPE DEVELOPMENTPARTNERSEDINAMNDATE:I HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION OR REPORT WAS PREPARED BYME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONALENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.MNLIC. NO.BRIAN M. WURDEMAN, P.E.10/25/20215311307/18/22 ED197050 Brian Stevens