HomeMy WebLinkAbout2025-06-25 Planning Commission Packet
Meeting location:
Edina City Hall
Council Chambers
4801 W. 50th St.
Edina, MN
Planning Commission Meeting Agenda
Wednesday, June 25, 2025
7:00 PM
Participate in the meeting:
Watch the meeting on cable TV or at YouTube.com/EdinaTV.
Provide feedback during Community Comment by calling 312-535-
8110. Enter access code 2865 819 9306. Password is 5454. Press *3 on
your telephone keypad when you would like to get in the queue to
speak. A staff member will unmute you when it is your turn.
Accessibility Support:
The City of Edina wants all residents to be comfortable being part of the
public process. If you need assistance in the way of hearing amplification, an
interpreter, large-print documents or something else, please call 952-927-
8861 at least 72 hours in advance of the meeting.
1. Call to Order
2. Roll Call
3. Approval of Meeting Agenda
4. Approval of Meeting Minutes
4.1. Minutes from Regular meeting May 28, 2025 and Special Work Session June 11, 2025
5. Community Comment
During "Community Comment," the Board/Commission will invite residents to share
issues or concerns that are not scheduled for a future public hearing. Items that are on
tonight's agenda may not be addressed during Community Comment. Individuals must
limit their comments to three minutes. The Chair may limit the number of speakers on
the same issue in the interest of time and topic. Individuals should not expect the Chair or
Board/Commission Members to respond to their comments tonight. Instead, the
Board/Commission might refer the matter to staff for consideration at a future meeting.
6. Public Hearing
During "Public Hearings," the Commission chair will ask for public testimony after staff
and/or applicants make their presentations. The following guidelines are in place to ensure
an efficient, fair, and respectful hearing; limit your testimony to three minutes and to the
matter under consideration; the Chair may modify times, as deemed necessary; avoid
repeating remarks or points of view made by previous speakers. The use of signs, clapping,
cheering or booing or any other form of verbal or nonverbal communication is not
allowed.
6.1. Setback variances, 4004 Grimes Ave.
Page 1 of 93
6.2. 316 Madison Avenue Subdivision with Variances
7. Chair and Member Comments
8. Staff Comments
9. Adjournment
Page 2 of 93
BOARD & COMMISSION
ITEM REPORT
Date: June 25, 2025 Item Activity: Approve
Meeting: Planning Commission
Agenda Number: 4.1
Prepared By: Liz Olson, Administrative Support
Specialist
Item Type: Minutes Department:
Item Title: Minutes from Regular meeting May 28, 2025 and Special Work Session June 11,
2025
Action Requested:
Approve both mintues.
Information/Background:
Supporting Documentation:
1. May 28, 2025 Regular Meeting
2. June 11, 2025 Special Work Session
Page 3 of 93
Draft Minutes☒
Approved Minutes☐
Approved Date: ___, 2025
Page 1 of 3
Minutes
City Of Edina, Minnesota
Planning Commission
Edina City Hall Council Chambers
May 28, 2025
I. Call To Order
Chair Bennett called the meeting to order at 7:00 p.m.
II. Roll Call
Answering the roll call were: Commissioners Alkire, Bornstein, Daye, Felt, Hahneman, Padilla, Smith, and
Chair Bennett. Staff Present: Cary Teague, Community Development Director, Kris Aaker, Assistant
Planner, and Liz Olson, Administrative Support Specialist.
Absent from the roll call: Commissioners Nelson, Jha, and Joncas.
III. Approval Of Meeting Agenda
Commissioner Padilla moved to approve the agenda for May 28, 2025. Commissioner Daye
seconded the motion. Motion carried unanimously.
IV. Approval Of Meeting Minutes
A. Minutes: Planning Commission, May 14, 2025
Commissioner Daye moved to approve the minutes from the May 14, 2025, meeting.
Commissioner Hahneman seconded the motion. Motion carried unanimously.
V. Community Comment
None.
VI. Public Hearings
A. Variance Request - 7202 Shannon Drive
Assistant Planner Aaker presented the request for a variance at 7202 Shannon Drive. Staff and
recommended approval of the variance, as requested, subject to the findings and conditions listed in the
staff report.
Appearing for the Applicant
Mr. Joshua Segal, 5414 Washburn Avenue South, addressed the Commission.
Page 4 of 93
Draft Minutes☒
Approved Minutes☐
Approved Date: ___, 2025
Page 2 of 3
Staff and the applicant answered Commission questions.
Public Hearing
None.
Commissioner Alkire moved to close the public hearing. Commissioner Smith seconded the
motion. Motion carried unanimously.
The Commission discussed the variance request and deemed the changes to be appropriate.
Motion
Commissioner Alkire moved that the Planning Commission approve the Variance Request as
outlined in the staff memo, subject to the conditions and findings therein. Commissioner Padilla
seconded the motion. Motion carried unanimously.
The official City website provides access to the Commission’s discussion regarding the variance request.
B. Comprehensive Plan Amendment, Rezoning, Preliminary Plat, and Site Plan – 5516
Vernon Avenue
Director Teague presented the request for 5516 Vernon Avenue, including a Comprehensive Plan
Amendment, rezoning, preliminary plat, and site plan. Staff recommends approval as requested, subject to
the findings and conditions listed in the staff report.
Appearing for the Applicant
Mr. Jordan Crockett, Rashad Kennedy, and Darion Fletcher of Abundance Properties presented a video of their
project and made a presentation to the Planning Commission.
The Commission asked questions of the staff and the applicants.
Public Hearing
Ms. Susan Carlson, 5508 Goya Lane, addressed the Commission expressing concerns about the plans.
Mr. Mark Kegel, 5529 Vernon Avenue, addressed the Commission and stated that he was not in favor of the
current development as presented.
Mr. Wayne Collins, 5532 Vernon Avenue, addressed the Commission with his concerns regarding the
development.
Commissioner Daye moved to close the public hearing. Commissioner Alkire seconded the
motion. Motion carried unanimously.
Page 5 of 93
Draft Minutes☒
Approved Minutes☐
Approved Date: ___, 2025
Page 3 of 3
Director Teague addressed the public’s concerns regarding the designation of the properties versus multi-
family.
The Commission reviewed the proposed Comprehensive Plan Amendment, Rezoning, Preliminary Plat,
and Site Plan.
Motion
Commissioner Smith moved that the Planning Commission recommend approval to the City
Council of the Comprehensive Plan Amendment, Rezoning, Preliminary Plat, and Site Plan as
outlined in the staff memo, subject to the conditions and findings therein. Commissioner Alkire
seconded the motion. Motion carried 6 ayes, 2 nays (Bornstein, Bennett).
The official City website provides access to the Commission’s discussion regarding the Comprehensive Plan
Amendment, Rezoning, Preliminary Plat, and Site Plan.
VII. Chair and Member Comments
Received.
VIII. Staff Comments
Received.
IX. Adjournment
Commissioner Felt moved to adjourn the May 28, 2025, Meeting of the Edina Planning
Commission at 8:52 p.m. Commissioner Hahneman seconded the motion. Motion carried
unanimously.
Page 6 of 93
Draft Minutes☒
Approved Minutes☐
Approved Date: ___, 2025
Page 1 of 1
Minutes
City Of Edina, Minnesota
Planning Commission
Special Work Session
Edina City Hall Community Room
June 11, 2025
I. Call To Order
Vice Chair Alkire called the meeting to order at 5:30 PM.
II. Roll Call
Answering the roll call were: Commissioners Alkire, Bornstein, Felt, and Padilla. Staff Present: Cary
Teague, Community Development Director, and Bill Neuendorf, Economic Development Manager.
Absent from the roll call: Commissioner Daye, Hahneman, Nelson, Smith; Student Commissioners Jha,
Joncas and Chair Bennett.
III. Meeting Topics
A. France Avenue Pedestrian Crossing
Economic Development Manager Neuendorf presented the France Avenue Pedestrian Crossing Plan. He
reviewed the plans and requested the Commission to evaluate and discuss them. He noted the overpass
was previously removed from the plans once the underpass was designed.
Staff answered Commission questions.
The Commission discussed the France Avenue Pedestrian Crossing, and the entire discussion can be heard
on the official City website.
Mr. Neuendorf noted that staff would be taking public comment until June 30, 2025. If the Commission
would like to write an advisory communication to inform the City Council as they make their decision,
that would be welcome but not required.
XI. Adjournment
Commissioner Felt moved to adjourn the June 11, 2025, Meeting of the Edina Planning
Commission at 6:38 p.m. Commissioner Bornstein seconded the motion. Motion carried
unanimously.
Page 7 of 93
BOARD & COMMISSION
ITEM REPORT
Date: June 25, 2025 Item Activity: Approve
Meeting: Planning Commission
Agenda Number: 6.1
Prepared By: Kris Aaker, Assistant City Planner
Item Type: Public Hearing Department: Community Development
Item Title: Setback variances, 4004 Grimes Ave.
Action Requested:
Approve or Deny the variances based on findings listed in the staff report.
Information/Background:
The request is for a 4.8-foot front yard setback variance from the 34.8-foot requirement to allow a
30-foot front yard setback for a garage addition instead of the required 34.75 ft. A 2.7-foot south
side yard setback variance from the 9-foot requirement to allow a 6.3-foot side setback for a 2nd
story addition above the south portion of the house located ar 4004 Grimes Ave. The proposed
additions meet all other requirements of Section 36-438 of the zoning code.
Better Together Public Input
Supporting Documentation:
1. Staff report
2. Photos
3. Applicant narrative
4. Project narrative
5. Drawings
6. Streetscape Photos
7. Staff Presentation
Page 8 of 93
June 25, 2025
PLANNING COMMISSION
Kris Aaker, Assistant Planner
B-25-09, Melissa and Jonathan Schaefer are requesting a 4.8-foot front yard setback variance
from the 34.8-foot requirement to allow a 30-foot front yard setback for a garage addition
instead of the required 34.75 ft and a 2.7-foot south side yard setback variance from the 9-foot
requirement to allow a 6.3-foot side setback for a 2nd story addition above the south portion
of the house. at 4004 Grimes Ave.
Information / Background:
The property at 4004 Grimes Ave. is a single-family residential rambler with an attached garage
built in 1953. The owners are proposing an addition to the front of the attached garage to increase
the depth and to add a 2nd floor living space above a southern portion of the home.
Front yard: A 4.8-foot front yard variance is requested to allow a reduction in front yard setback to
increase the depth of the garage while reducing current setback by 4.8 ft to the street. The
homeowners are requesting a variance to allow adequate depth for interior car parking. Currently
homes along the west side of Grimes are relatively lined up with one another. The following are
the front yard setback requirements in an established neighborhood:
Sec. 36-439. - Special requirements. Special setback requirements for single dwelling unit lots.
a. Established front street setback. When more than 25 percent of the lots on one side of a
street between street intersections, on one side of a street that ends in a cul-de-sac, or on one
side of a dead-end street, are occupied by dwelling units, the front street setback for any lot shall
be determined as follows:
2. If there are existing dwelling units on abutting lots on both sides of the lot that both have a
front street setback on the same street, the front street setback shall be the average of the front
street setbacks of the dwelling units on the two abutting lots on the same street; or the front
street setback shall be the average front street setback of all other dwelling units on the same
side of that street, between intersections.
Page 9 of 93
STAFF REPORT Page 2
Side yard: The required side yard setback is 18’-8” total with no less than 9 ft on one side. The
existing home is nonconforming with total side yard setbacks of 11’ – 3 ½”, with a setback on the
north side of 5 ft and south side of 6.3 ft, (the property is nonconforming regarding both side
yard setbacks). The minimum setback requirement applies to the proposed 2nd floor with the
alternate setback standard that allows continuation of existing nonconforming setbacks not
applicable for a 2nd floor addition to the rambler.
Surrounding Land Uses
Single Unit residential homes and a school, zoned R-1 and guided low-density residential
Planning
Guide Plan designation: Low Density Residential
Zoning: R-1, Single Dwelling Unit District
Compliance Table
City Standard Proposed
North Side–
Yard
East Front –
Yard
South Side–
Yard
West Rear–
Yard
18’-8” with no less than
9 feet on one side
34.8 feet
9 feet
25 feet
5 feet existing
(existing nonconforming)
*30 feet
*6.3 feet
51 feet
Building Height 30 feet 27 feet
Building Coverage
Lots greater than 9,000sf
Impervious Surface Coverage
25%
50%
23.7%
37.1%
First Floor Elevation 901.5 901.5
*Requires a variance
Page 10 of 93
STAFF REPORT Page 3
PRIMARY ISSUES & STAFF RECOMMENDATION
Optional Actions
A case could be made both for denial and approval of this project. Below provides options for the
Planning Commission to consider:
Primary Issues/Variance Denial
No, the proposed variance isn’t justified.
Minnesota Statutes and Section 36-98 of the Edina Zoning Ordinance require that a
variance shall not be granted unless the following findings are made:
1.The variance would not be in harmony with the general purposes and intent of the
ordinance.
Front yard: Staff believe that the purpose and intent of the front yard setback ordinance is to
maintain consistent front yard spacing from the street for homes along a block. In general,
the homes align with one another along the 4000 block of Grimes with the average front
yard setback not an impacting variable on a property. The front wall of the subject home
conforms, and the addition to the garage is proposed to be closer to the street than the
other homes along that side of the block. The proposal will decrease the setback of the front
wall of the subject home by 4.8 ft.
Side yard: The south side yard setback requirement of 9 ft can be achieved by an indent of
the 2nd floor addition. Previous plans submitted to staff illustrated a conforming 2nd floor, so
it is not the conditions of the lot that are driving the need for a variance. The 2nd floor
setback request is to accommodate a design for maximum south facing windows and light
exposure which is self-created and not a result of some unique aspect of the lot.
2.The variance would be consistent with the Comprehensive Plan.
The Comprehensive Plan guides the property for low density residential, which includes
single dwelling units as a primary use. The use of the property will remain a single dwelling
unit. The request will allow garage and living space expansion and make interior remodeling
modifications to accommodate the preferences of the homeowner. Staff find that the
requested variance is consistent with the Comprehensive Plan.
3.There are no practical difficulties in complying with the ordinance. The term
“practical difficulties” means the following:
i.The property owner proposes to use the property in a reasonable manner not
permitted by the Zoning Ordinance.
Front yard: The applicant is seeking to improve the interior of the home and wishes
to expand farther to the east on the main floor and above the first floor near the
Page 11 of 93
STAFF REPORT Page 4
south side yard. The front yard variance is needed to address the established
average front yard setback requirement given homes along the block. The location
of the existing garage does not allow for a front addition to meet the requirements
of the Zoning Ordinance. A remodel prior to the current owners purchasing the
home carved out space in the interior back area of the garage to make a mudroom
and laundry room. This remodel made the length of the garage very shallow. The
homeowners propose moving the laundry room to use that space as storage for
sports equipment. The owners would like to keep the space as interior space and
add to the length of the garage to provide some clearance in front of and behind
vehicles. There appears to be an opportunity for expansion in the interior of the
garage space by eliminating proposed storage.
Side yard: The homeowner desires to add a ½ story addition on top of the south
portion of the house. Plans were shared with staff illustrating a centered 2nd floor
addition that conforms to the side yard setback ordinance. It has been demonstrated
a conforming 2nd floor is possible without the need for a variance.
Staff do not find the request to be reasonable. There are no practical difficulties that
prevents the interior remodel of the garage or 2nd floor expansion.
ii.The plight of the landowner is not due to circumstances unique to the
property and may be created by the landowner.
The property is not unique on the block with consistent front yard setbacks as
compared with the other homes fronting Grimes. The homes along the west side of
grimes are evenly spaced from the street.
The 2nd floor can be accommodated without the need for a variance.
iii.The variance, if granted, may possibly alter the essential character of the
locality.
The variance may alter the essential character of the locality. The additions are well
outside the minimum setbacks and may encourage other similar properties to
request similar variances.
Denial
Deny the request for a 4.8-foot front yard setback variance from the 34.8-foot requirement to allow a 30-
foot front yard setback for a garage addition instead of the required 34.75 ft and a 2.7-foot south side yard
setback variance from the 9-foot requirement to allow a 6.3-foot side setback for a 2nd story addition above
the south portion of the house. at 4004 Grimes Ave. Denial is based on the following findings:
Page 12 of 93
STAFF REPORT Page 5
1. The proposal does not meet the standards for variance. There appears
to be an opportunity for expansion in the interior of the garage space,
and it is possible to accommodate a second floor without the need for
a variance.
2. There are no practical difficulties preventing the interior remodel of
the garage or 2nd floor expansion.
3. When considering the property, there are no unique circumstances
present. The property currently conforms to the front yard setback
and can maintain the required side yard setback for a 2nd floor addition.
4. Granting variance may alter the essential character of the
neighborhood by continuing nonconforming setbacks and reducing the
front yard setback. The additions are well outside the minimum
setbacks and may encourage other similar properties to request similar
variances.
Primary Issues/Variance Approval
Yes, the proposed variance is justified.
Minnesota Statutes and Section 36-98 of the Edina Zoning Ordinance require that a
variance shall not be granted unless the following findings are made:
The variance would be in harmony with the general purposes and intent of the
ordinance.
Front yard: Staff believe that the purpose and intent of the front yard setback ordinance is to
maintain consistent front yard spacing from the street of homes along a block. In general, the
homes align with one another along the 4000 block of Grimes with the average front yard
setback not an impacting variable on a property. The front wall of the subject home
conforms, with the garage addition proposed to be closer to the street than the other
homes along the same side of the block. All aspects of the front façade conform to the front
yard setback with the exception of the 4.8 ft garage extension. Most of the front wall of the
subject home will maintain the required front yard setback without interruption to the
streetscape.
Side yard: Side yard setbacks have changed since the time when the home was built in 1953.
The ordinances allowed narrower side yard setbacks for both the 1st and 2nd floors. It is a
common assumption that an addition can be built directly over the existing first floor of a
home. Edina’s ordinances allow for an adjustment to the required setback by allowing an
“alternate setback standard” that provides an addition with ability to match an existing
nonconforming setback; however, the addition must be on the same floor as the
nonconforming setback. There has been discussion by Planning Commissioners that it might
be appropriate to amend zoning to allow 2nd floor additions at matching 1st floor setbacks.
The variance would be consistent with the Comprehensive Plan.
Page 13 of 93
STAFF REPORT Page 6
The Comprehensive Plan guides the property for low density residential, which includes
single dwelling units as a primary use. The use of the property will remain a single dwelling
unit. The request will allow garage and living space expansion and make interior remodeling
modifications to accommodate the preferences of the homeowner. Staff find that the
requested variance is consistent with the Comprehensive Plan.
There are practical difficulties in complying with the ordinance. The term “practical difficulties”
means the following:
iv.The property owner proposes to use the property in a reasonable manner not
permitted by the Zoning Ordinance.
Front yard: The applicant is seeking to improve the interior spaces of the home and
wishes to expand farther to the east to accommodate enough space to comfortably
store cars. The variance is needed to address the established average front yard
setback requirement given the garage’s shallow depth. The nonconforming location
of the existing building does not allow for an addition. The garage is currently at the
minimum front yard setback and is nonconforming by 4’-8” to the side yard. There
are limited, if any, options available for a conforming garage expansion, perhaps only
an interior remodel.
Side yard: Staff finds the side yard setback request to be reasonable. The ordinance
allows a matching nonconforming setback on the same floor as the nonconformity.
The ordinance does not apply to a new 2nd floor addition if there is no 2nd floor
existing. There has been discussion to review the ordinance to possibly allow
expansion above an existing building footprint that is nonconforming and was
conforming at time of original construction. A 2nd floor would have been allowed at
current south setback in 1953 when the home was built. It is reasonable to allow a
matching 2nd floor expansion.
Remodeling and adding onto the home is a practical and sustainable solution that is
less intrusive to the neighborhood than a tear-down/re-build new home.
v.The plight of the landowner is due to circumstances unique to the property
not created by the landowner.
Front yard: The property is unique in that it is on a block with consistent front yard
setbacks. There are no variables in front yard setback along the block. The proposal
by the applicant presents a reasonable location for the addition that cannot be
modified to conform to zoning requirements. The front yard setback circumstance
was not created by the applicant and is unique to the property given the shallow
garage depth.
Side yard: The first floor is nonconforming, was constructed in 1953 under different
setback standards. The second floor is subjected to deeper side yard setbacks even
though the 2nd floor would match the legally nonconforming setback and would not
Page 14 of 93
STAFF REPORT Page 7
reduce the side setback or be any closer to the side yard. The ordinance change to a
deeper setback was not a created condition of the property owner.
vi.The variance, if granted, will not alter the essential character of the locality.
The variance will not alter the essential character of the locality. The proposed
additions will reduce setbacks only along the front garage width with the remainder
of the home at the required front yard setback and the 2nd floor will match an
existing nonconforming setback from the south side yard. There are many varied
residences in Morningside, some that have built new floor levels above existing, one-
story homes, some that have added to the back of their homes, some that have been
torn down to build new and some that are original to the area. Morningside is a
mixture of lot sizes and configurations, housing styles and years of construction. The
additions will continue the eclectic character of Morningside.
Approval
The request for a 4.8-foot front yard setback variance from the 34.8-foot requirement to allow a 30-foot
front yard setback for a garage addition instead of the required 34.75 ft and a 2.7-foot south side setback
variance from the 9-foot requirement to allow a 6.3-foot side setback for a 2nd story addition above the
south portion of the house. at 4004 Grimes Ave. Approval is based on the following findings:
1. The front yard setback practical difficulty is caused by the location of the existing
nonconforming garage. There are limited, if any, options available for a
conforming garage expansion.
2. It is reasonable to allow a matching 2nd floor expansion. The request is
reasonable given that a 2nd floor would have been allowed at the current south
setback in 1953 when the home was originally built.
3. There are circumstances that are unique to the subject property. Those unique
circumstances include keeping the home by remodeling and adding a small 2nd
floor which is both practical and sustainable for the neighborhood.
4. The proposal would not alter the essential character of the neighborhood. There
are similar sized buildings with nonconforming setbacks within the Morningside
neighborhood.
Any approval is subject to the following conditions:
•Subject to plans and survey date stamped May 23, 2025.
•Compliance with the tree ordinance.
Deadline for a City decision: July 23, 2025.
Page 15 of 93
STAFF REPORT Page 8
Page 16 of 93
Page 17 of 93
Page 18 of 93
Page 19 of 93
Page 20 of 93
Page 21 of 93
VARIANCE APPLICATION
The variance would be in harmony with the general purpose and intent of the ordinance.
Yes
The variance would be consistent with the Comprehensive Plan
Yes, the residence will remain a single family residence, which is consistent with the
Comprehensive plan.
The property owner proposed to use the property in a reasonable manner not permitted
by the ordinance
This property would remain single family residential. The proposed size of the garage is
consistent with modest garage sizes. The existing garage faces the street and will continue to
face the street. The upper level addition is consistent with other additions in the
neighborhood.
There are practical difficulties complying with the ordinance
The plight of the landowner is due to circumstances unique to the property not created by the
landowner.
The home was built in 1953 prior to current zoning requirements for residential zoning. The
homeowner would like to take advantage of the existing structure to build their addition.
The mudroom and laundry room were built into the garage space by prior homeowner and
these homeowners are hoping to make this situation more effective.
The variance will not alter the essential character of the locality
Currently 4004 Grimes is a one story home. Melissa & Jon Schaefer would like to add a 1/2
story above the main floor to create a bedroom suite, do a modest main floor remodel and
increase their garage space.
There are many varied residences in Morningside, some that have built new floor levels above
existing 1 story homes, some that have added on to the back of their homes, some that have
been torn down to build new and some that are original to the area.
This prior owner’s mudroom and laundry room remodel left them with a garage space that has
16’-4” interior clearance on one side and 17’- 3” on the other. The internal width of the garage
is 18’-6”. These dimensions allow for little to no clearance around their vehicles.
We talked at length about the best approach to getting additional space in the garage and
decided that moving the laundry would allow for storage of sports gear and equipment.
Relocating the garage on this lot while keeping this home layout is not practical.
Page 22 of 93
Relocating the laundry and mudroom in their entirety also seems unfeasible.
The owners believe that remodeling the existing home is worthwhile and decided to ask for a
variance in order to extend the garage 4’-9” to the 30’-0” front yard setback and maintain the
existing 5’-0” side yard setback to the north.
We feel by pulling the face of the garage forward does not alter the character of the locality.
The Morningside area has many homes with front yard setbacks that differ from the norm.
Page 23 of 93
EXISTING BUILDING COVERAGEHOUSE2,085 SQ. FT.SHED62 SQ. FT.TOTAL EXISTING BUILDINGS 2,147 SQ. FT.AREA OF LOT9,449 SQ. FT.BUILDING COVERAGE22.7%EXISTING HARDCOVERHOUSE2,085 SQ. FT.DRIVEWAY/WALKS/PATIO/STOOP 1,316 SQ. FT.SHED62 SQ. FT.PLAY DECK23 SQ. FT.AC PAD8 SQ. FT.TOTAL EXISTING HARDCOVER 3,494 SQ. FT.AREA OF LOT9,449 SQ. FT.LOT COVERAGE37.0%PROPOSED BUILDING COVERAGEHOUSE2,180 SQ. FT.SHED62 SQ. FT.FRONT COVERED PORCH122 SQ. FT.TOTAL PROPOSED BUILDINGS 2,364 SQ. FT.AREA OF LOT9,449 SQ. FT.BUILDING COVERAGE25.0%PROPOSED HARDCOVERHOUSE2,180 SQ. FT.DRIVEWAY/WALKS/PATIO/STEPS 1,183 SQ. FT.SHED62 SQ. FT.PLAY DECK23 SQ. FT.AC PAD8 SQ. FT.FRONT COVERED PORCH122 SQ. FT.TOTAL PROPOSED HARDCOVER 3,578 SQ. FT.AREA OF LOT9,449 SQ. FT.LOT COVERAGE37.8%NOTE: THE HARDCOVER ITEMS SHOWN ABOVE ARE THOSE THAT WEREOBSERVED AND THAT ARE TYPICALLY COUNTED AS HARDCOVER INMOST CITIES. BEFORE MOVING FORWARD WITH PLANNING ORCONSTRUCTION, BE SURE TO VERIFY THESE ITEMS WITH THE CITY.LEGAL DESCRIPTION:Lot 2, Block 2, Morningside Oaks, Hennepin County, MinnesotaSCOPE OF WORK & LIMITATIONS:1. Showing the length and direction of boundary lines of the legal description listed above.The scope of our services does not include determining what you own, which is a legalmatter. Please check the legal description with your records or consult with competentlegal counsel, if necessary, to make sure that it is correct and that any matters of record,such as easements, that you wish to be included on the survey have been shown.2. Showing the location of observed existing improvements we deem necessary for thesurvey.3. Setting survey markers or verifying existing survey markers to establish the corners ofthe property.4. Showing and tabulating impervious surface coverage of the lot for your review and forthe review of such governmental agencies that may have jurisdiction over theserequirements to verify they are correctly shown before proceeding with construction.5. Showing elevations on the site at selected locations to give some indication of thetopography of the site. We have also provided a benchmark for your use in determiningelevations for construction on this site. The elevations shown relate only to thebenchmark provided on this survey. Use that benchmark and check at least one otherfeature shown on the survey when determining other elevations for use on this site orbefore beginning construction.6. This survey has been completed without the benefit of a current title commitment. Theremay be existing easements or other encumbrances that would be revealed by a currenttitle commitment. Therefore, this survey does not purport to show any easements orencumbrances other than the ones shown hereon.7. While we show a proposed location for this home or addition, we are not as familiarwith your proposed plans as you, your architect, or the builder are. Review ourproposed location of the improvements and proposed yard grades carefully to verify thatthey match your plans before construction begins. Also, we are not as familiar withlocal codes and minimum requirements as the local building and zoning officials in thiscommunity are. Be sure to show this survey to said officials, or any other officials thatmay have jurisdiction over the proposed improvements and obtain their approvals beforebeginning construction or planning improvements to the property.8. Note that all building dimensions and building tie dimensions to the property lines, aretaken from the siding and or stucco of the building.STANDARD SYMBOLS & CONVENTIONS:"●" Denotes iron survey marker, found, unless otherwise noted.#43503LICENSE NO.Wayne W. PreuhsDATES1APRIL 16, 2025Deephaven, Minnesota 55391Phone (952) 474-796418202 Minnetonka Blvd. Suite 401Web: www.advsur.comAdvanceSurveying & Engineering Co.MELISSA & JONATHAN SCHAEFER4004 GRIMES AVE.CLIENT/JOB ADDRESSEDINA, MNSHEET TITLEPROPOSED SURVEYSHEET NO.SHEET 1 OF 1DWG ORIENTATIONSCALE250531 JRDRAWING NUMBER20'10'0APRIL 9, 2025DATE SURVEYED:APRIL 16, 2025DATE DRAFTED:SHEET SIZE: 17 X 22Updated Submittal 5-23-25Planning DIvisionPage 24 of 93
SCALE 1 /4" = 1' - 0"
1 LOWER LEVEL EXISTING
0' 2' 4'12'
FURNACE
WH
WS
ELECT
PANEL
FIREPLACEBASE7'-4"
FAMILY
004
CPT
7'-4"
MECH
007
CONC
7'-4"
STORAGE
008
CONC
7'-4"
BEDROOM
000
CPT
7'-4"
BATH
002
TILE
7'-4"
CLO
006
CPT
7'-4"
HALL
005
CPT
STAIR
013
WOOD
7'-4"
FAMILY
003
CPT
CRAWL
SPACE
UNEXCAVATED
7'-4"
CLO
001
CPT
2 x 10's @ 16" OC EXIST
2 x 10's @ 16" OC EXIST
EXIST BEAMEXIST BEAMEXISTPOSTEXISTPOSTEXISTPOST31'-3"13'-112"12'-7"13'-712"19'-6"58'-912"34'-61 2"
23'-6"10'-111 2"
WALL LEGEND
EXISTING WALLS
EXISTING MASONRY
NEW WALLS
HALF HEIGHT WALL
NO WORK SHADED AREAS
2 x 10's @ 16" OC EXIST
4'-9"
FILL IN AT
EXISTING
WINDOW
2 NEW POSTS FOR
PORCH
NEW BEAM FOR
PORCH FLOOR
FRAMING
LEDGER BOARD
FOR PORCH
FRAMING
FOOTING FOR GARAGE EXTENSION
TIE INTO EXISTING
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A2.0
LOWER LEVEL
EXISTING PLAN
Updated Submittal
5-23-25
Planning DIvision
Page 25 of 93
SCALE 1 /4" = 1' - 0"
1 MAIN LEVEL EXISTING
0' 2' 4'12'
WALL LEGEND
EXISTING WALLS
EXISTING MASONRY
NEW WALLS
HALF HEIGHT WALL
NO WORK SHADED AREAS
2-SIDED
FIREPLACE
REMOVE PORTION
OF WALL AROUND
CLOSET
REMOVE CLOSET
AND RAISED
STORAGE
ATTIC ACCESS
STONE
VENEER OVER
MASONRY
WASHER DRYER
EXTERIOR
PLANTER
10'-0"
GARAGE
118
CONC
8'-0"
LIVING
100
WOOD
8'-0"
ENTRY
101
TILE
8'-0"
CLO
102
-
8'-0"
BATH
103
TILE
8'-0"
BEDROOM
104
WOOD8'-0"
CLO
105
-
8'-0"
CLO
106
-
8'-0"
BEDROOM
107
WOOD
8'-0"
HALL
111
WOOD
8'-0"
HALL
108
WOOD
8'-0"
PRIMARY
109
WOOD
8'-0"
CLO
110
WOOD
-
STAIR
013
WOOD
8'-0"
DINING
114
WOOD
8'-0"
KITCHEN
115
WOOD
8'-0"
CLO
112
WOOD
8'-0"
MUDROOM
116
TILE
8'-0"
LAUNDRY
117
TILE
EXISTPOSTEXISTPOSTEXISTPOST31'-3"13'-112"12'-7"13'-612"19'-7"58'-912"7'-10"14'-8"36'-312"34'-7"
4'-8"
6'-11"16'-9"
17'-3"
16'-4"
10'-1112"
3'-4"
REMOVE CLOSET
SYSTEM THIS
ROOM AND SAVE
FOR REUSE
PATIO
PAVERS
STOOP
PAVERS
REPLACE EXISTING
FRONT DOOR
REMOVE CONCRETE
STOOP AND STEPS
REMOVE LOW WALL
REMOVE PLANTER
REMOVE EAST WALL OF
GARAGE, GARAGE DOORS
REMOVE BRICK PAVERS AS
NEEDED FOR ACCESS TO NEW
FOOTINGS. SAVE FOR OWNER'S
REUSE
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A2.1
MAIN LEVEL
EXISTING PLAN
Updated Submittal
5-23-25
Planning DIvision
Page 26 of 93
MAIN LEVEL PROPOSED
0' 2' 4'12'
2-SIDED WD
BURNING
FIREPLACE
WASHER
DRYER
8'-0"
LAUNDRY
110
E. WOOD
-
STAIR
203
WOODAC FRONT YARD VARIANCE
NEEDED FOR 4'-9" ADDITION
SETBACK VARIANCE OF 4'-0"
NEEDED FOR THIS PORTION
OF GARAGE
ATTACH CEILING JSTS
ABOVE THIS AREA TO
BOTTOM OF NEW 2ND
FLOOR JOISTS
REMOVE WASHER &
DRYER ALONG WITH
PLUMBING LINES &
DRYER VENT.
31'-3"13'-112"12'-7"13'-612"19'-7"58'-912"7'-10"14'-8"36'-312"39'-4"
6'-11"16'-9"10'-111 2"
ROUGH IN PLUMBING
SUPPLIES & DRAIN FOR
FUTURE LAUNDRY. PROVIDE
DUCTING TO EXTERIOR FOR
FUTURE DRYER.
REMAINDER OF LAUNDRY
FINISH BY OWNER
4'-9"1'-9916"16'-0"1'-912"SCALE 1 /4" = 1' - 0"
1
REMOVE BRICK PAVERS AS
NEEDED TO POUR NEW
FOOTINGS. REINSTALL TO NEW
APRON. SAVE REMAINDER FOR
OWNER'S REUSE
CONCRETE APRON & INFILL @
GARAGE SLAB
REMOVE EAST WALL OF
GARAGE, PROVIDE NEW
FOOTING, CONCRETE FLOOR,
FRAMING & ROOFING ALONG
WITH DOUBLE WIDE GARAGE
DOOR
OWNER WILL
FILL SIDEWALK
WITH LEFTOVER
PAVERS
WALL LEGEND
EXISTING WALLS
EXISTING MASONRY
NEW WALLS
HALF HEIGHT WALL
NO WORK SHADED AREAS
10'-0"
GARAGE
118
E CONC
8'-0"
ENTRY
101
E TILE
8'-0"
BATH
103
E TILE
8'-0"
BEDROOM
104
E WOOD
8'-0"
BEDROOM
107
E WOOD
8'-0"
HALL
111
WOOD
8'-0"
HALL
108
E WOOD
8'-0"
FAMILY
109
E WOOD
-
STAIR
013
WOOD
8'-0"
DINING
114
E WOOD
8'-0"
KITCHEN
115
E WOOD
8'-0"
MUDROOM
116
E TILE
8'-0"
LAUNDRY
117
TILE
PATIO
E PAVERS
STOOP
E PAVERS
8'-0"
CLO
105
-
8'-0"
CLO
106
-3"412"11'-912"412"3"4"4"41 4"4'-10"
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A2.2
MAIN LEVEL
PROPOSED PLAN
Updated Submittal
5-23-25
Planning DIvision
Page 27 of 93
SCALE 1 /4" = 1' - 0"
1 UPPER LEVEL PROPOSED
0' 2' 4'12'
WALL LEGEND
EXISTING WALLS
EXISTING MASONRY
NEW WALLS
HALF HEIGHT WALL
NO WORK SHADED AREAS
-
STAIR
203
-
9'-0"8'-312"641 SQ FT
FINISHED 26'-112"7'-112"7'-112"7'-812"3'-0"31'-3"
8'-3"14'-9"5'-3"3'-0"
31'-21 2"
14'-11 2"3'-1"3'-0"2'-0"
VARIES
BEDROOM
203
HDWD
9'-0"
BATH
203
TILE
9'-0"
CLOSET
203
HDWDMECH
Issue:
M ERIWETHER I NC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A2.3
UPPER LEVEL
PROPOSED PLAN
Updated Submittal
5-23-25
Planning DIvision
Page 28 of 93
SCALE 1 /4" = 1' - 0"
1 ROOF PLAN PROPOSED
0' 2' 4'12'
NEW ROOF OVER GARAGE
EXTENSION. PROVIDE NEW
ASPHALT SHINGLES ON NORTH
SIDE OF HOME
ROOF OVER PORCH STANDING
SEAM METAL PANEL
LINE OF WALLS BELOW
ROOF OVER UPPER LEVEL
ADDITION TO BE STANDING
SEAM METAL PANEL
OVERFRAME EXISTING ROOF
TO EXTEND HIP ROOF AT
GARAGE
Issue:
M ERI WETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A2.4
PROPOSED
ROOF PLAN
Updated Submittal
5-23-25
Planning DIvision
Page 29 of 93
EAST ELEVATION EXISTING
4
4
0
4
1RST FLOOR FIN 871.7'
1RST FLOOR CEILING
8'-0"LOWER LEVEL FIN 863.38'-438"SCALE 1 /4" = 1' - 0"
2
SCALE 1 /4" = 1' - 0"
1
EAST ELEVATION PROPOSED
0' 2' 4'12'
2ND FLOOR FIN 880.1'
1RST FLOOR FIN 871.7'
1RST FLOOR CEILING
8'-0"4 0 0 427'-012"AVG EXIST GRADE ELEVATION6'-10"1'-434"EXTEND CHIMNEY TO 2'-0" ABOVE ROOF W/IN 10'-0"
NEW METAL ROOFING AT ADDITION
BOARD AND BATTEN SIDING
WHOLE HOUSE TO BE PAINTED
NEW FRONT DOOR
NEW DOUBLE GARAGE DOOR
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A3.0
EAST ELEVATION
Updated Submittal
5-23-25
Planning DIvision
Page 30 of 93
SCALE 1 /4" = 1' - 0"
1 SOUTH ELEVATION EXISTING
1RST FLOOR FIN 871.7'
1RST FLOOR CEILING
8'-0"LOWER LEVEL FIN 863.38'-438"SCALE 1 /4" = 1' - 0"
2
SCALE 1 /4" = 1' - 0"
2 SOUTH ELEVATION PROPOSED
0' 2' 4'12'
2ND FLOOR FIN 880.1'
1RST FLOOR FIN 871.7'1'-434"TO WINDOW
1RST FLOOR CEILING
8'-0"3'-0"1'-6"22'-11"27'-012"AVERAGE EXISTING GRADE ELEVATION6'-10"BOARD AND BATTEN SIDING
NEW BAND BOARD BETWEEN EXISTING SIDING AND
NEW SIDING
WHOLE HOUSE TO BE PAINTED
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A3.1
SOUTH ELEVATION
Updated Submittal
5-23-25
Planning DIvision
Page 31 of 93
SCALE 1 /4" = 1' - 0"
1 WEST ELEVATION EXISTING
1RST FLOOR FIN 871.7'
1RST FLOOR CEILING
8'-0"LOWER LEVEL FIN 863.38'-438"SCALE 1 /4" = 1' - 0"
2
SCALE 1 /4" = 1' - 0"
3 WEST ELEVATION PROPOSED
0' 2' 4'12'6'-10"2ND FLOOR FIN 880.1'
1RST FLOOR FIN 871.7'
TO WINDOW
1RST FLOOR CEILING
8'-0"1'-434"EXTEND CHIMNEY TO 2'-0" ABOVE ROOF W/IN 10'-0"
NEW METAL ROOFING AT ADDITION
BOARD AND BATTEN SIDING
WHOLE HOUSE TO BE PAINTED
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A3.2
WEST ELEVATION
Updated Submittal
5-23-25
Planning DIvision
Page 32 of 93
NORTH ELEVATION EXISTING
1RST FLOOR FIN 871.7'
1RST FLOOR CEILING
8'-0"LOWER LEVEL FIN 863.38'-438"SCALE 1 /4" = 1' - 0"
2
SCALE 1 /4" = 1' - 0"
1
NORTH ELEVATION PROPOSED
0' 2' 4'12'
2ND FLOOR FIN 880.1'
1RST FLOOR FIN 871.7'
TO WINDOW
1RST FLOOR CEILING
8'-0"1'-434"6'-10"Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A3.3
NORTH ELEVATION
Updated Submittal
5-23-25
Planning DIvision
Page 33 of 93
2ND FLR 880.1'
1ST FLR 871.7'9'-434"4
4
0
4
LL FLR 863.3'8'-358"SCALE 3 / 32 " = 1' - 0"
2 PROPOSED STREETSCAPE
SCALE 3 / 32 " = 1' - 0"
1 EXISTING STREETSCAPE GRIMES
1ST FLR 871.7'8'-0"LL FLR 863.3'8'-358"1ST CLG
4 0 0 4
Issue:
M ERIWETHER INC
4116 Grimes Ave So
Edina, MN 55416
Cell 612.850.1670
Schaefer Residence4004 Grimes AveSo.Edina, MN 55416Date
SCHEMATIC DESIGN 4.11.2025
2025 Meriwether Felt Architect, Edina MN
PLANNING SUBMITTAL 5.23.2025
DESIGN DEVELOPMENT 5.21.2025
A3.4
STREET ELEVATION
Updated Submittal
5-23-25
Planning DIvision
Page 34 of 93
Page 35 of 93
EdinaMN.gov
4004 GRIMES AVE.
FRONT YARD AND SIDE YARD SETBACK VARIANCE REQUEST
Page 36 of 93
Existing street photos
Page 37 of 93
Site Survey with proposed
improvements
Page 38 of 93
Block FY Avg = 35’
Page 39 of 93
Site Survey
Page 40 of 93
Compliance
Page 41 of 93
Basement Level
Page 42 of 93
Existing Main Floor
Page 43 of 93
Interior Garage Space: 16’-9” Deep
Page 44 of 93
Proposed Main Floor
Page 45 of 93
2nd Floor Addition
Page 46 of 93
Front Elevations
Page 47 of 93
South Side Elevations
Page 48 of 93
Rear/West Elevations
Page 49 of 93
North/Side Elevations
Page 50 of 93
Front Renderings
Page 51 of 93
Rendering with Street Scape Photo
Page 52 of 93
Page 53 of 93
Page 54 of 93
Page 55 of 93
Page 56 of 93
BOARD & COMMISSION
ITEM REPORT
Date: June 25, 2025 Item Activity: Approve
Meeting: Planning Commission
Agenda Number: 6.2
Prepared By: Addison Lewis, Community Development
Coordinator
Item Type: Public Hearing Department: Community Development
Item Title: 316 Madison Avenue Subdivision with Variances
Action Requested:
Motion to recommend approval of the preliminary and final plat with variances to lot area and lot
width for both lots and variance to lot depth for Lot 2 subject to the conditions in the staff report.
Information/Background:
Homes Within Reach is proposing to subdivide the property at 316 Madison Avenue into two
lots. The two proposed lots would both have dimensions of approximately 46’x130’. The parcel
was originally platted as two lots with these dimensions that were combined. The proposed
subdivision would re-establish the original lot sizes, which are consistent with the majority of other
lots on the 300 block of Madison Avenue (12 out of 18 other lots on the block are approximately the
same dimensions). The existing home on the property is proposed to remain and one new buildable
lot for a single-family home would be created. This proposal requires the following:
1. Preliminary and final plat to re-plat the property into two lots
2. Variance from Sec. 36-437 of the Edina City Code to allow lot area of 5,988 sq. ft. and 6,004
sq. ft. where 9,000 sq. ft. is required
3. Variance from Sec. 36-437 of the Edina City Code to allow lot width of 45.96 feet for both
lots where 75 feet is required
4. Variance from Sec. 36-437 of the Edina City Code to allow lot depth of 130.27 feet for one
of the lots where 130.57 feet is required.
Supporting Documentation:
1. Staff Report
2. Location Map
3. Plans
4. Applicant Narrative
5. Hennepin County Historic Half Section Map
6. Staff Presentation
Page 57 of 93
June 25, 2025
PLANNING COMMISSION
Addison Lewis, Community Development Coordinator
2025.09, Subdivision and variances at 316 Madison Avenue
Information / Background:
Homes Within Reach is proposing to subdivide the property at 316 Madison Avenue into two lots.
The two proposed lots would both have dimensions of approximately 46’x130’. The parcel was
originally platted as two lots with these dimensions that were combined. The proposed subdivision
would re-establish the original lot sizes, which are consistent with the majority of other lots on the
300 block of Madison Avenue (12 out of 18 other lots on the block are approximately the same
dimensions). The existing home on the property is proposed to remain and one new buildable lot
for a single-family home would be created. This proposal requires the following:
1. Preliminary and final plat to re-plat the property into two lots
2. Variance from Sec. 36-437 of the Edina City Code to allow lot area of 5,988 sq. ft. and
6,004 sq. ft. where 9,000 sq. ft. is required
3. Variance from Sec. 36-437 of the Edina City Code to allow lot width of 45.96 feet for both
lots where 75 feet is required
4. Variance from Sec. 36-437 of the Edina City Code to allow lot depth of 130.27 feet for one
of the lots where 130.57 feet is required.
Surrounding Land Uses
Northerly: Single-Family; zoned R-1; guided Low Density Residential
Easterly: Single-Family; zoned R-1; guided Low Density Residential
Southerly: Single-Family; zoned R-1; guided Low Density Residential
Westerly: Single-Family; zoned R-1; guided Low Density Residential
Page 58 of 93
STAFF REPORT Page 2
Existing Site Features
The property is 11,992 square feet in area and contains a single-family home on the north half
of the property. The southern half contains vegetation and several trees. The property is
adjacent to an alley on the west side.
Planning
Guide Plan designation: Low Density Residential
Zoning: R-1, Single Dwelling Unit District
Lot Dimensions
Section 36-437 of the Edina City Code establishes minimum standards for lot area, lot width, and
lot depth within the R-1 district. The minimum lot area is 9,000 square feet, the minimum lot
width is 75 feet, and the minimum lot depth is 120 feet. For all three of these standards, if the
median within the neighborhood is greater, then the standard is the median. “Neighborhood”
means all lots in the R-1 district which are wholly or partially within 500 feet of the perimeter of
the proposed plat or subdivision, excluding lots used for parks, conditional uses, or lots separated
from the proposed plat by the right-of-way of either T.H. 100 or T.H. 62. In this case, the standard
for lot depth is the median.
Area Lot Width Depth
Required 9,000 s.f. 75 feet 130.57 feet
Feet Median (lots within 500’) 8,120 s.f. 60 feet 130.57 feet
Lot 1 6,004 s.f.* 45.96 feet* 130.61 feet
Lot 2 5,988 s.f.* 45.96 feet* 130.27 feet*
* Variance Required
Page 59 of 93
STAFF REPORT Page 3
Grading/Drainage and Utilities
The Engineering Department has reviewed the proposed plans and found them acceptable at this
stage. Final plans for grading, drainage, and utilities will be reviewed at the time of building permit.
Trees
Based on the plans, it appears some tree removal will be necessary to accommodate a new home.
The applicant would be subject to the tree protection ordinance. Final plans will be subject to
review by the City Forrester at the time of building permit.
Park Dedication
Because this property was originally platted as two lots that were combined, no park dedication is
required.
History of Subdivision Requests with Variances
The City of Edina has considered several subdivision requests with variances. (See attached area
map.) The following is the history in the past 19 years:
History of Recent Subdivisions with Variances
1. In 2006, the property at 5901 France Avenue was approved variances to build four
(4) 66-foot-wide lots consistent with the area. (Median = 9,269 s.f. & 73 feet
wide.)
2. In 2008, 6120 Brookview Avenue was proposed to be divided into two (2) 50-foot
lots; however, the applicant withdrew the request before action was taken.
(Median = 6,700 s.f. & 50 feet wide.)
3. In 2009, a 100-foot lot at 5920 Oaklawn was approved variances to divide into two
(2) 50-foot lots. (Median = 6,699 s.f. & 50 feet wide.)
4. In 2011, the property at 5829 Brookview was approved variances to divide into
two (2) 50-foot lots. (Median = 6,769 s.f. & 50 feet wide.)
5. In 2012, the property at 6109 Oaklawn was denied the request to subdivide the
property into two (2) 50-foot lots. (Median = 6,701 s.f. & 50 feet wide.)
Page 60 of 93
STAFF REPORT Page 4
6. In 2012, 6120 Brookview was again proposed for subdivision. That request was
denied. (Median = 6,700 s.f. & 50 feet wide.)
7. In 2012, 5945 Concord was denied the request to subdivide the property into two
(2) 50-foot lots. (Median = 10,028 s.f. & 77 feet wide.)
8. In 2015, a 100-foot lot at 5825 Ashcroft Avenue was approved variances to divide
into two (2) 50-foot lots. (Median = 6,790 s.f. & 50 feet wide.)
9 In 2015, 5945 Concord was approved for a request to subdivide the property into
two (2) 50-foot lots. (Median = 10,028 s.f. & 77 feet wide.)
10. In 2016, 5845 Kellogg Avenue was denied a request to subdivide the property into
two (2) 50-foot lots. (Median = 6,715 s.f. & 50 feet wide.)
11. In 2017, 6124 Ewing Avenue was approved for a request to subdivide into two (2)
lots with lot width and area variances. (Median = 11,500 s.f. & 80 feet wide.)
12. In 2017, 5404 Park Place was approved for a request to subdivide into two (2) lots
with lot width variances from 75 feet to 65 feet for each lot; and lot area variances
from 9,000 square feet to 8,705 and 8,840 square feet. (Median = 8,107 s.f. &
width was 60 feet wide.)
13. In 2019, 5841 Oaklawn was approved for a request to subdivide into two (2) lots
with lot width variances from 75 feet to 50 feet for one lot; and lot area variances
from 9,000 square feet to 8,793 and 6,694 square feet.
14. In 2019, 4625 Lexington was approved for a request to subdivide into two (2) lots
with lot width variances from 75 feet to 60 feet for both lots, and lot area variances
from 9,306 square feet to 8,106 and 8,128 square feet. (Median area - 9,306
square feet, median lot depth - 135 feet, and the median lot width 68 feet)
15. In 2020, 5928 Ashcroft was denied a request to subdivide into two (2) lots with lot
width variances from 75 feet to 50 feet for both lots, and lot area variances from
9,000 square feet to 6,813 and 6,790 square feet. (Median area – 8,841 s.f.,
median lot depth – 135 and median width was 66 feet.)
16. In 2020, 5928 Abbott Avenue was approved for a two-lot subdivision with lot
width variances from 75 feet to 50 feet for both lots, lot area variance from 9,000
square feet to 6,391 and 6,331 square feet, and lot depth variances from 135 feet to
127 feet for both lots. (Median lot area – 6,745 square feet, median lot depth -
129.9 feet, and the median lot width – 50 feet.)
17. In 2020, 7413 and 7425 York Terrace was approved to subdivide two lots into
three lots with a lot width variance from 75 feet to 59 feet for Lot 1; lot depth
variances from 135 feet to 132 feet for Lot 1 and to 107 for Lots 2 and 3; and lot
area variances from 9,962 square feet to 8,909 square feet for Lot 1, to 8,328 square
Page 61 of 93
STAFF REPORT Page 5
feet for Lot 2, and 8,859 square feet for Lot 3. (Median lot area – 9,962 square
feet, median lot depth – 133, median lot width – 75 feet).
18. In 2021, 5209 Minnehaha Blvd was approved for a request to subdivide into two
(2) lots with lot width variances from 75 feet to 60 feet for both lots. (Median lot
area – 10,846 square feet, median lot depth – 163 feet, median lot width – 70
feet).
19. In 2022, 6416 McCauley Circle was approved for a request to subdivide into two
(2) lots with a lot area variance from 18,731 square feet to 16,431 square feet for
one of the lots, lot width variance from 102 feet to 80 feet for one of the lots, and
lot depth variances from 181 feet to 120 and 100 feet for both lots. (Median lot
area 18,731 square feet, median lot depth – 181 feet, median lot width – 102
feet)
20. In 2024, 5120 and 5124 Hankerson Avenue was approved for a request to
subdivide two lots into three lots with lot area, width, and depth variances. The
area of the proposed lots was 6,509, 6,515, and 6,520 square feet. All lots were 50
feet wide and 130 feet deep. (Median area – 6,504 square feet, median lot
depth – 130 feet, median lot width – 50 feet)
In instances when subdivisions were denied, the area immediately surrounding the site
contained a wide variety of lot sizes. In instances when subdivisions were approved, the
requesting lot was oversized (twice as large) compared to lots in the immediate area. In this
case, the subject property is a double lot and 12 of the 18 other lots on the block have similar
dimensions to the lots being proposed.
PRIMARY ISSUES & STAFF RECOMENDATION
Primary Issues
Are the proposed variances justified?
Yes, staff does believe the requested variances are justified.
Minnesota Statutes and Section 36-98 of the Edina Zoning Ordinance require that a
variance shall not be granted unless the following findings are made:
1. The variance would be in harmony with the general purposes and intent of the
ordinance.
The purpose and intent of the ordinance is to establish minimum lot sizes that are similar
with surrounding properties. The lots in this neighborhood were platted prior to Edina’s
existing standards for lot area, width and depth. Many lot lines have shifted over time and
some lots have been combined; however, all lots in this neighborhood were originally platted
with approximately the same dimensions (46’x130’) as the lots being proposed. This is why
Page 62 of 93
STAFF REPORT Page 6
12 out of 18 other lots on the 300 block of Madison Avenue have these same dimensions as
the lots being proposed. The other lots are either double lots (like the subject property) or
lots that have been added to from another lot. In this case, the variances would allow for lot
dimensions that are compatible with the surrounding area. Criteria met.
2. The variances would be consistent with the Comprehensive Plan.
The Comprehensive Plan guides the property for Low Density Residential Use. The
principal use of the property would still be as a single-family home and the property would
remain zoned R-1.
The request could also be viewed as advancing the following goals in the Comprehensive
Plan:
Land Use Chapter
• Goal 1: Encourage infill and redevelopment that optimizes use of city infrastructure,
complement community character, and respond to needs at all stages of life.
Housing Chapter
• Goal 2: Encourage the development and maintenance of a range of housing options affordable
to residents at all income levels and life stages.
o Promote owner-occupied units over rental units when providing affordable housing.
• Goal 4: Support the development of a wide range of housing options to meet the diverse needs
of and preferences of the existing and future Edina community.
o Retain and expand housing ownership options, while also supporting a balance between
ownership and rental households.
Staff find the requested variances would be consistent with the Comprehensive Plan.
Criteria met.
3. There are practical difficulties in complying with the ordinance. The term “practical
difficulties” means the following:
i. The property owner proposes to use the property in a reasonable manner not
permitted by the Zoning Ordinance.
The property owner is proposing to subdivide the property into two lots. The
property was originally platted as two lots with the same lot dimensions. The lot
dimensions are similar with many other lots in the neighborhood. Staff find the
request to be reasonable. Criteria met.
ii. The plight of the landowner is due to circumstances unique to the property
not created by the landowner.
Page 63 of 93
STAFF REPORT Page 7
The property is somewhat unique in that it is currently a double lot in a
neighborhood that was platted prior to the current lot area, width and depth
standards being adopted. The lot standards in the zoning ordinance do not reflect
the existing conditions of the neighborhood. The lots were not combined by the
current owner. Criteria met.
iii. The variance, if granted, will not alter the essential character of the locality.
The variances will not alter the essential character of the locality. There are 12 out
of 18 other properties on the 300 block of Madison Avenue that have approximately
the same lot dimensions as those being proposed. Criteria met.
Options for Consideration
Denial
Recommend that the City Council deny the proposed preliminary and final plat with variances to
lot area and lot width for both lots and variance to lot depth for Lot 2. Denial is based on the
following findings:
1. The proposed lot area and width for both lots and depth for Lot 2 do not conform to the
standards of the zoning ordinance.
2. The requested variances are not in harmony with the general purposes and intent of the
ordinance. The proposed lot dimensions no longer align with the City of Edina’s
expectations for single-family development.
3. The plight of the landowner is not due to circumstances unique to the property. There are
many other lots in Edina that were platted prior to adoption of the current standards for
lot area, width, and depth.
Approval
Recommend the City Council approve the preliminary and final plat with variances to lot area and
lot width for both lots and variance to lot depth for Lot 2. Approval is based on the following
findings:
1. The variances are in harmony with the general purposes and intent of the ordinance. The
proposed lot sizes would be compatible with other lots in the neighborhood.
2. The variances are consistent with the Comprehensive Plan by advancing land use and
housing goals as stated in the staff report.
3. The property owner proposes to use the property in a reasonable manner not permitted
by the Zoning Ordinance. The property was originally platted as two lots and the variances
would allow for lot sizes consistent with the original plat.
4. The plight of the landowner is due to circumstances unique to the property not created by
the landowner. The property is currently a double lot in a neighborhood that was platted
prior to the current lot area, width, and depth standards. The standards in the zoning
Page 64 of 93
STAFF REPORT Page 8
ordinance do not reflect the existing conditions of the neighborhood. The lots were not
combined by the current owner.
5. The variance will not alter the essential character of the locality. There are currently 12
out of 18 other properties on the 300 block of Maddison Avenue that have approximately
the same dimensions as those being proposed.
6. If the variances are granted, the proposed plat complies with the requirements of Chapter
32 (Subdivisions) and Chapter 36 (Zoning) of the City Code.
Approval is subject to the following conditions:
1. Compliance with the tree protection requirements in Section 10-82 of the City Code.
2. Prior to issuance of a building permit, the following items must be submitted:
a. Evidence that the final plat has been filed with Hennepin County. If the plat is not
filed with Hennepin County within one year from the date of approval by the City
Council, the plat shall be deemed abandoned and of no effect.
b. Submit evidence of a Nine Mile Creek Watershed District approval.
c. Driveway Entrance permit must be obtained from the Edina Engineering
Department.
d. Utility hook-ups are subject to review by the City Engineer.
Staff Recommendation
Staff recommend approval of the preliminary and final plat with variances to lot area and lot width
for both lots and variance to lot depth for Lot 2 subject to the conditions in this report.
Deadline for a City decision: September 23, 2025.
Page 65 of 93
Page 66 of 93
Page 67 of 93
932.46933.63TC932.92932.34932.52932.84933.24932.82933.09933.40E933.18TRD20932.47TRD32932.77932.99933.32932.97933.12932.06932.06933.10932.5932.49932.15930.3929.25930.08931.31930.51930.56931.88TRD8932.12932.55AC932.67G932.15932.19929.08929.38929.66931.91932.22930.74929.93TRC26931.78932.10931.78931.26930.60TC931.08Flow Line930.29MH930.76Rim930.44930.94931.24932.41932.77932.24932.43932.22FC930.9345.94 45.94
46.00
14.410.017.2Garage28.614.12.546.00 N 00°16'35" W 92.00
N 89°04'23" E 130.44N 00°09'06" E 91.88 N 89°06'02" E 130.78N 89°02'45" E 130.1010.64.326.593093293293
0 932931933
931
9339319309.05.05.027.8932.5933.0932.5tw932.3bw931.4bituminous
deckResidence316Residence320Garage320Alley
Madison Avenue STo Be RemovedWall To Be Removed6.0tw931.5tw932.0tw932.5tw933.8bw931.8933932
933
932Proposed-wallProposed-wall1Proposed ResidenceD r i v e w a yS i d e w a l kPorch
933.6
933.8 931.5932.0concrete
Drivewayegress well10%±C o n c r e t eStepsS i d e w a l k6'0"
13'0"13'0"62'6"20'0"20'6"12'0"42'0"1'6"1'6"36.19.0A/C Pad929.912in"inv=927.15Deck931cmpinv=928.71931.5F:\survey\west minneapolis heights - hennepin\10-11-6 west minneapolis heights\01 Surveying - 90871\01 CAD\01 Source\01 Survey Base.dwgBasis forbearings isassumedSurveyors Certificatex000.0Denotes Wood Hub Set for excavation onlyDenotes Existing ElevationDenotes Proposed ElevationDenotes Surface DrainageDenotes Iron MonumentDenotes Found Iron MonumentDenotes Proposed ContoursDenotes Existing ContoursDenotes Silt Fence or Bio RollsNOTE: Proposed grades are subject to results of soil tests.Proposed building information must be checked withapproved building plan and development or gradingplan before excavation and construction.Proposed grades shown on this survey areinterpolations of proposed contours from thedrainage, grading and/or development plans.NOTE: The relationship between proposed floorelevations to be verified by builder.NOTE: The only easements shown are from plats ofrecord or information provided by client.Benchmark: Benchmark 165 is locatedon the southeast part of the intersectionof Belmore Lane & Madison Avenue S.Top Nut Hydrant = 936.14Drawn BySignedGregory R. Prasch, Minn. Reg. No. 24992Scale: 1" = 20'F.B.No.Project No.I certify that this survey, plan, or report was prepared by me or under mydirect supervision and that I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota.revAddress:Existing Legal Description7601 73rd Avenue NorthMinneapolis, Minnesota 55428(763) 560-3093DemarcInc.com90871A-Tree Protection & Site Plan Survey For:316 Madison Ave SEdina, MNSurveyed this 13th day of February 2025. WEST HENNEPIN AFFORDABLE HOUSING Lot 11, Block 6, WEST MINNEAPOLISHEIGHTSHennepin County, MinnesotaProperty located in Section30, Township 117, Range 21,Hennepin County, MinnesotaZoning:Property is Zoned R1-Single Dwelling UnitSetback RequirementsFront: 30 feet or average of adjacentSide Street: 15 feetSide Yard: 5 feetRear Yard: 25 feetProposed Top of FoundationProposed Garage FloorProposed Basement FloorType of BuildingProposed First Floor Elevation935.36934.1933.8926.42Full Basement100 Year Flood Elevation Per City ofEdina = 931.3 NGVD 2903-07-25 House Footprint ChangeNOTE: All Bottom of Wall Elevationswill match Existing Grade04-01-25 Tree ListDenotes Tree Protection FenceProposed-HardcoverLot Area5,988 sq ftProp-Building1,745 sq ftProp-Egress13 sq ftProp-Porch w/Steps34 sq ftProp-Deck51 sq ftProp-Walk(s)213 sq ftProp-A/C Pad8 sq ftProp-Driveway615 sq ftTotal2,679 sq ftPercentage44.74%Proposed-Building CoverageLot Area5,988 sq ftProp-Building1,745 sq ftProp-Porch34 sq ftPorch-Allowance-34 sq ftTotal1,745 sq ftPercentage29.14%04-30-25 Revisions05-07-25 StormwaterPage 68 of 93
Page 69 of 93
Page 70 of 93
932.46933.63TC933.65LIP933.85GL933.92TC934.25TC933.25TC932.92932.34932.52932.84933.24932.82933.09933.40E933.18TRD20932.47TRD32932.77932.99933.32932.97933.12932.06932.06933.10932.5932.49932.15930.3929.25930.08931.31930.51930.56931.88TRD8932.12932.55AC932.67G932.15932.19929.08929.38929.66931.91932.22930.74929.93TRC26931.78932.10931.78931.26930.60TC931.08Flow Line930.29MH930.76Rim930.44930.94931.24932.41932.77932.24932.43932.22FC930.9345.94 45.9446.0014.410.017.2Garage28.614.12.546.00 N 00°16'35" W 92.00N 89°04'23" E 130.44N 00°09'06" E 91.88 N 89°06'02" E 130.78N 89°02'45" E 130.1010.64.326.5930932932930 932931933931 9339319309.05.05.027.8932.5933.0932.5tw932.3bw931.4bituminousdeckResidence316Residence320Garage320AlleyMadison Avenue SWall To Be RemovedPARCEL BPARCEL A6.0tw931.5tw932.0tw932.5tw933.8bw931.8933932933 932Proposed-wallProposed-wall1Proposed ResidenceD r i v e w a yS i d e w a l kPorch 933.6933.8 931.5932.0concreteDrivewayegress well10%±C o n c r e t eStepsS i d e w a l k6'0"13'0"13'0"62'6"20'0"20'6"12'0"42'0"1'6"1'6"36.19.0A/C Pad929.912in"inv=927.15Deck931cmpinv=928.71931.5FLOW45°STRAW SEDIMENTCONTROL LOG1 IN X 2 IN X 24 IN LONG WOODEN STAKES.STAKES SHALL BE DRIVEN THROUGH THEBACK HALF OF THE SEDIMENT CONTROL LOGAT AN ANGLE OF 45 DEGREES WITH THETOP OF THE STAKE POINTING UPSTREAM.BACKFILL AND COMPACT SOILFROM TRENCH ON UPGRADIENTSIDE OF SEDIMENT CONTROL LOGPLACE SEDIMENT CONTROLLOG IN SHALLOW TRENCH(1 IN - 2 IN DEPTH)8 IN - 10 IN EMBEDMENT DEPTHSPACE BETWEEN STAKES SHALL BE A MAXIMUM OF 1 FT FOR DITCH CHECKSOR 2 FT FOR OTHER APPLICATIONS.BIOROLLSNOT TO SCALE6C1EXISTING GROUNDWEST HENNEPINAFFORDABLE HOUSING5100 THIMSEN AVE #120MINNETONKA, MINNESOTA 55345SCALE IN FEET2004024" NYLOPLAST CATCH BASINRIM = 930.96INV(NW,E) = 929.11INV(SW) = 928.71SILT FENCE ORBIO-ROLLS (TYP.)PER 1/C1 AND 7/C1FINALGRADECLEAN AGGREGATE (1 1/2"± RIVERROCK), PEA GRAVEL, OR SAND,(<5% FINES)ADS GEOSYNTHETICNONWOVEN GEOTEXTILEOR APPROVED EQUAL.928.2(LEVEL BOTTOM)FRENCH DRAINS ("B") CROSS SECTIONNOT TO SCALE4.5'MIN 4" PEA GRAVEL, 3/4" ROCK, OR GEOTEXTILENATIVE FILL DEPTH VARIESMIN 4" TOPSOILLANDSCAPEGRATE=933.0932.7 (LEVEL TOP)6" PERFORATEDDRAINTILEINSPECTION PORTINTO FRENCH DRAINMIN 4" PEA GRAVEL,3/4" ROCK, ORGEOTEXTILE5C1PROPOSEDROCK STABILIZING EXITFINALGRADECLEAN AGGREGATE (1 1/2"± RIVERROCK), PEA GRAVEL, OR SAND,(<5% FINES)ADS GEOSYNTHETICNONWOVEN GEOTEXTILEOR APPROVED EQUAL.927.7(LEVEL BOTTOM)FRENCH DRAINS ("A") CROSS SECTIONNOT TO SCALE4.5'MIN 4" PEA GRAVEL, 3/4" ROCK, OR GEOTEXTILENATIVE FILL DEPTH VARIESMIN 4" TOPSOILLANDSCAPEGRATE=932.5932.2 (LEVEL TOP)6" PERFORATEDDRAINTILEINSPECTION PORTINTO FRENCH DRAINMIN 4" PEA GRAVEL,3/4" ROCK, ORGEOTEXTILE3C1FRENCH DRAIN "A"15'X14'X4.5'PER DETAIL 4/C1FRENCH DRAIN "B"18'X10'X4.5'PER DETAIL 6/C16" PERFORATED DRAINTILE (TYP.)6" PERFORATED DRAINTILE (TYP.)F:\survey\west minneapolis heights - hennepin\10-11-6 west minneapolis heights\01 Surveying - 90871\01 CAD\01 Source\01 Survey Base.dwg
C1 OF C1DATE:LIC. NO.:SHEET NO.PROJECT: 90871REVISIONSDESIGNED BY:DRAWN BY:CHECKED BY:EROSION AND SEDIMENTCONTROL PLANI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATEOF MINNESOTA.JEFFREY A. PRASCH, P.E.03.18.2552706ABLJAPGRPINLET PROTECTIONNOT TO SCALE2C1MINIMUM DOUBLE STITCHEDSEAMS ALL AROUND SIDEPIECES AND ON FLAP POCKETSFRONT, BACK, ANDBOTTOM TO BEMADE FROM SINGLEPIECE OF FABRICOVERFLOW HOLES (2 IN X 4IN HOLE SHALL BE HEAT CUTINTO ALL FOUR SIDE PANELS)USE REBAR OR STEEL RODFOR REMOVAL (FOR INLETSWITH CAST CURB BOXREPLACE ROD WITH WOOD 2IN X 4 IN). EXTEND 10 INBEYOND GRATE WIDTH ONBOTH SIDES, LENGTHVARIES. SECURE TO GRATEWITH WIRE OR PLASTIC TIES.LW12 W12 IN8 ININLET SPECIFICATIONS AS PERTHE PLAN DIMENSION LENGTH ANDWIDTH TO MATCH FLAP POCKET12 L5 FT MINIMUM LENGTH POSTAT 6 FT MAXIMUM SPACINGPLASTIC ZIP TIES (50 LBSTENSILE) LOCATED IN TOP 8 INGEOTEXTILE FABRIC,36 IN WIDETIRE COMPACTION ZONEMACHINE SLICE8 IN - 12 IN DEPTHFLOWFLOWSILT FENCE (MACHINE SLICED)NOT TO SCALE1C12 FT MINIMUMPOST EMBEDMENTEXISTING GROUNDROCK STABILIZING EXIT (IF NECESSARY)NOT TO SCALE4C1PUBLIC ROADSURFACE FLOWCRUSHED ROCKPER SPECIFICATIONEXISTING GROUND6 IN MINIMUM
GEOTEXTILEFABRICTAPER EDGESAT 1:11 IN - 2 IN CRUSHED ROCKRADIUS ASREQUIRED20' MINIMUM LENGTH
EXIT WIDTH ASREQUIREDEROSION CONTROL NOTES:1.ALL EROSION AND SEDIMENT CONTROL BMP'S (I.E. SILT FENCE, BIO-ROLLS, ROCK CONSTRUCTION EXIT, INLET PROTECTION, ETC.) SHALL BE INSTALLED PRIOR TO THE COMMENCEMENT OF ANYCONSTRUCTION ACTIVITY.2.INLET PROTECTION SHALL BE INSTALLED AT ANY INLET THAT MAY RECEIVE RUNOFF FROM THE DISTURBED AREAS OF THE PROJECT. INLET PROTECTION MAY BE REMOVED FOR A PARTICULAR INLET IF ASPECIFIC SAFETY CONCERN (FLOODING / FREEZING) HAS BEEN IDENTIFIED. THE PERMITTED MUST RECEIVE WRITTEN CORRESPONDENCE FROM THE CITY ENGINEER VERIFYING THE NEED FORREMOVAL.3.INSTALL SEDIMENT CONTROL BMP'S, SUCH AS SILT FENCE, AROUND ALL STOCKPILES.4.RETAIN AND PROTECT AS MUCH NATURAL VEGETATION AS FEASIBLE. WHEN VEGETATION IS REMOVED DURING DEVELOPMENT, THE EXPOSED CONDITION OF LAND SHALL BE KEPT TO THE SHORTESTPRACTICAL PERIOD OF TIME, BUT NOT LONGER THAN 60 DAYS. ANY EXPOSED AREAS EXCEEDING THIS TIME-FRAME SHALL BE TEMPORARILY STABILIZED (STRAW MULCH, WOODCHIPS, ROCK). AREASBEING USED FOR MATERIAL STORAGE AND AREAS UNDER CONSTRUCTION ARE EXEMPT FROM TEMPORARY STABILIZATION.5.ANY STEEP SLOPES (3H : 1V OR STEEPER) EXPOSED DURING CONSTRUCTION SHALL BE PROTECTED WITH TEMPORARY VEGETATION, MULCHING OR BY OTHER MEANS ACCEPTABLE TO THE BUILDINGOFFICIAL WITHIN 14 DAYS OF CEASING LAND DISTURBING ACTIVITIES ON THE STEEP SLOPES. STOCKPILES MAY BE PROTECTED BY AN ANCHORED TARP OR PLASTIC SHEET.6.PROVIDE DUST CONTROL AS NECESSARY. DUST CONTROL CAN INCLUDE WATER.7.REMOVE ALL SOILS AND SEDIMENTS TRACKED OR OTHERWISE DEPOSITED ONTO PUBLIC PAVEMENT AREAS ON A DAILY BASIS OR AS NEEDED.8.ALL EROSION AND SEDIMENT CONTROL BMP'S SHALL BE INSPECTED EVERY 7 DAYS, OR WITHIN 24 HOURS OF ALL RAIN EVENTS GREATER THAN 1.0" IN 24 HOURS. CORRECTIVE ACTION REQUIRED SHALLBE INITIATED WITHIN 24 HOURS.9.SILT FENCE, BIO-ROLLS AND INLET PROTECTION DEVICES MUST BE REPAIRED, REPLACED OR SUPPLEMENTED WHEN THEY BECOME NONFUNCTIONAL OR THE SEDIMENT REACHES 1/3 THE HEIGHT OF THEDEVICE. THESE REPAIRS MUST BE MADE WITHIN 24 HOURS OF DISCOVERY, OR AS SOON AS FIELD CONDITIONS ALLOW.10.AFTER FINAL GRADING HAS BEEN COMPLETED, EXPOSED SOILS MUST BE PERMANENTLY STABILIZED AS SOON AS POSSIBLE. PERMANENT STABILIZATION SHALL CONSIST OF 4 INCHES TOPSOIL, ANDSEED, MULCH AND FERTILIZER APPLIED BY METHODS AND RATES RECOMMENDED IN MN/DOT SPECIFICATION 2575 AND MN/DOT SEEDING MANUAL, OR SOD. THE SEED MIX SHALL BE MN/DOT 25-151.11.NO CONCRETE WASHOUT ALLOWED ON SITE, TRUCK BASED SELF CONTAINMENT WASHOUT DEVICES REQUIRED.12.OIL STAINS ON CITY STREETS SHALL BE CLEANED UP WITH FLOOR DRY, AND DISPOSED OF AS A HAZARDOUS WASTE MATERIAL.13.ALL HAZARDOUS WASTE SHALL BE STORED CLEANED UP AND DISPOSED OF PER EPA STANDARDS.14.ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE MAINTAINED UNTIL ALL DISTURBED AREAS HAVE BEEN PERMANENTLY STABILIZED.15.ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE REMOVED FROM THE SITE AFTER PERMANENT STABILIZATION HAS BEEN ESTABLISHED.16.TEMPORARY PUMPED DISCHARGE POLLUTION PREVENTION TECHNIQUES: "DANDY DEWATERING BAG" BROCK WHITE CO. USA.17.CONTACT PERSON FOR SITE CLEANLINESS AND MAINTENANCE OF THE EROSION AND SEDIMENT CONTROLS: TIM UZZELL (612) 386-5217.GENERAL GRADING NOTES:1.THE STANDARD SPECIFICATIONS FOR THE CITY OF EDINA SHALL APPLY EXCEPT WHERE MODIFIED BY THESE DOCUMENTS.2."GOPHER STATE ONE CALL" (1-800-252-1166) SHALL BE NOTIFIED BY THE CONTRACTOR 48 HOURS PRIOR TO ANY EXCAVATION.3.PRIOR TO ANY CONSTRUCTION, THE GRADING CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES WITH UTILITYCOMPANIES. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY WITH ANY CONFLICTS.4.THE GRADING CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE ON THE SITE AT ALL TIMES.5.EXISTING TOPSOIL SHALL BE SALVAGED TO PROVIDE 4" TOPSOIL COVERAGE OVER ALL DISTURBED AREAS TO BE REVEGETATED.6.THE BUILDING PAD MUST BE PROVIDED WITH POSITIVE DRAINAGE. THIS WORK SHALL BE INCIDENTAL TO THE GRADING CONTRACT.7.AFTER THE SILT FENCE HAS BEEN REMOVED REMAINING SEDIMENT SHALL BE SMOOTHED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED ORSODDED AS DIRECTED BY THE CITY ENGINEER.8.NO FINISHED SLOPE SHALL EXCEED 4H : 1V UNLESS OTHERWISE NOTED.9.PERMITEE MUST MINIMIZE SOIL COMPACTION. METHODS OF MINIMIZING SOIL COMPACTION INCLUDE THE USE OF TRACKED EQUIPMENT.7601 73rd Avenue NorthMinneapolis, Minnesota 55428(763) 560-3093DemarcInc.comLOT 10-11, BLOCK 6WEST MINNEAPOLIS HEIGHTS316 MADISON AVENUE SOUTHEDINA, MNINV = 931.7INV = 932.2CONNECT TO EXISTINGCATCH BASININV = 926.796" PERFORATED DRAINTILE05.07.25CLIENT COMMENTSPage 71 of 93
932.46933.63TC933.65TC934.25932.34932.52932.84933.24932.82933.09933.40E933.18TRD20932.47TRD32932.77932.99933.32932.97933.12932.06932.06933.10932.5932.49932.15930.3929.25930.08931.31930.51930.56931.88TRD8932.12932.55AC932.67G932.15932.19929.38929.66931.91932.22930.74929.93TRC26931.78932.10931.78931.26930.60TC931.08Flow Line930.29MH930.76Rim930.44930.94931.24932.41932.77932.24932.43932.22FC930.9345.94 45.94
46.00
14.410.017.2Garage28.614.12.546.00 N 00°16'35" W 92.00N 89°04'23" E 130.44N 00°09'06" E 91.88 N 89°06'02" E 130.78N 89°02'45" E 130.1010.64.326.593093293293
0 932931933
931
933931930929.912in"inv=927.15cmpinv=928.711012B L O C K 160' Right-a-Way20.915.712.0 Right-of-Way1210bituminousdeck
Residence316Residence320Garage320Madison Avenue S Garage312Residence312South line of Lot 11, Block 6,West Minneapolis HeightsProposed Drainage
& Utility Easement
F:\survey\west minneapolis heights - hennepin\10-11-6 west minneapolis heights\01 Surveying - 90871\01 CAD\01 Source\01 Survey Base.dwgFile No.Certification Legal DescriptionPRELIMINARY PLAT Zoning & Development InformationMiscellaneous NotesPersonnel basis of bearings is assumedLegendx000.0PRELIMINARY PLAT - Whahlt EstatesF.B. No. xxxx inv. 90871A7601 73rd Avenue NorthMinneapolis, Minnesota 55428(763) 560-3093DemarcInc.comSCALE IN FEET20040 Signed: ____________________________________________ Gregory R. Prasch Registration No. 24992The only easements shown are from plats of record or information provided by client.I certify that this plan, specification, or report was prepared by me or under my direct supervisionand that I am a duly Licensed land Surveyor under the laws of the State of Minnesota.Existing Zoning Classification - R-1 (Single Dwelling Unit District)Refer to City code for additional requirements and variance information.Proposed Number of Lots = 2Area of proposed: Lot 1, Block 1 = 6,004 sq.ft Lot 2, Block 1 = 5,988 sq.ftLot Width of Proposed: Lot 1, Block 1 = 45.96 feet Lot 2, Block 1 = 45.96 feetLot Depth of Proposed: Lot 1, Block 1 = 130.61 feet Lot 2, Block 1 = 130.27 feet Current Right-of-Way (Madison Avenue S = 60 sq.ft Current Right-of-Way (alley) = 12 sq.ftSurveyor:DemarcSurveying and Engineering7601 73rd Avenue N.Brooklyn Park, MN 55428Attn: Greg Praschphone: 763-560-3093fax: 763-560-3522e-mail: gregprasch@demarcinc.comProperty is in Flood Zone "X" (an Area of minimal flood hazard) per FEMA FloodZone Map No. 27053C0342F, dated 11/04/2016.MN 1MN 2MN 3MN 4MN 5MN 6Denotes Found Iron MonumentDenotes Iron Monument SetBollardLightPower PoleSanitary ManholeStorm ManholeWater ManholeCatch BasinGas MainUnderground CommunicationsUnderground ElectricSanitary SewerStorm SewerWatermainOverhead WiresDenotes Existing ContoursThe land surveyed covers the entire parcel and there are no gaps oroverlaps with adjacent parcels.West Hennepin Affordable Housing5100 Thimsen AVENUE #120Minnetonka, MN 55345Whahlt Estatesdrawn by:AHDeveloper:West Hennepin AffordableHousing Land Trust5100 Thimsen AVENUE #120Minnetonka, MN 55345Attn: Brenda Lano Wolke952.401.7071Property Owner:West Hennepin AffordableHousing Land Trust5100 Thimsen AVENUE #120Minnetonka, MN 55345Property Address:316 Madison Avenue S, Edina, MN 55343Property Identification Number:3011721220025Total Area of Parcel = 11,992 sq.ftBenchmark: Benchmark 165 is located on the southeast part of the intersection ofBelmore Lane & Madison Avenue S.Top Nut Hydrant = 936.14Lots 10 & 11, Block 6, WEST MINNEAPOLIS HEIGHTSHennepin County, MinnesotaBEING 10 FEET IN WIDTH AND ADJOINING RIGHTOF WAY LINES AND 5 FEET IN WIDTH ANDADJOINING INTERIOR LOT AND ALLEY LINES.1010 55R/W LineLot Line Proposed Drainage & Utility Easements are shown thus:Revision Summary5/27/2025 City commentsPage 72 of 93
N 00°16'35" W 92.00N 00°09'06" E 91.88 N 89°06'02" E 130.7845.9445.9446.00 46.00N 89°02'33" E 130.10N 89°04'23" E 130.441212606012B L O C K 1Measured92.00 PlatSOUTH LINE OF LOT 11, BLOCK 6, WEST MINNEAPOLIS HEIGHTS1010Drainage & Utility EasementFound SpikeDrainage & Utility Easement555 5 5555 55F:\survey\west minneapolis heights - hennepin\10-11-6 west minneapolis heights\01 Surveying - 90871\01 CAD\01 Source\03 Final Plat.dwg
WHAHLT ESTATESC. R. DOC. NO.___________________________CITY COUNCIL, CITY OF EDINA, MINNESOTAThis plat of WHAHLT ESTATES was approved and accepted by the City Council of the City of Edina, Minnesota, at a regular meeting thereof held this______ day of _________________________, 20_____, and said plat isin compliance with the provisions of Minnesota Statutes, Section 505.03, Subdivision 2. City Council, City of Champlin, Minnesota By _____________________________________________, Mayor By _____________________________________________, ManagerCOUNTY AUDITOR, Hennepin County, MinnesotaI hereby certify that taxes payable in _________ and prior years have been paid for land described on this plat, dated this _______ day of ______________________, 20______. Daniel Rogan, Hennepin County Auditor By _________________________________________ DeputySURVEY DIVISION, Hennepin County, MinnesotaPursuant to Minnesota Statutes, Sec. 383B.565 (1969) this plat has been approved this ______ day of _______________________, 20______. Chris F. Mavis, Hennepin County Surveyor By __________________________________________COUNTY RECORDER, Hennepin County, MinnesotaI hereby certify that the within plat of WHAHLT ESTATES recorded in this office this _________ day of_______________________, 20______, at_______o'clock_____M. Amber Bougie, Hennepin County Recorder By__________________________________________DeputyI Gregory R. Prasch do hereby certify that this plat was prepared by me or under my direct supervision; that I am a duly Licensed Land Surveyor in the State of Minnesota; that this plat is a correct representation of the boundary survey; that all mathematicaldata and labels are correctly designated on this plat; that all monuments depicted on this plat have been, or will be correctly set within one year; that all water boundaries and wet lands as defined in Minnesota Statutes, Section 505.01, Subd. 3, as of the dateof this certificate are shown and labeled on this plat; and all public ways are shown and labeled on this plat.Dated this ____________day of ____________________, 20 ______. ___________________________________________ Gregory R. Prasch, Licensed Land Surveyor Minnesota License No. 24992STATE OF MINNESOTACOUNTY OF HENNEPINThis instrument was acknowledged before me on this ______ day of _______________________, 20_______ by Gregory R. Prasch. . Signature of Notary __________________________________ (Notary's Printed Name)_______________________________ Notary Public, ________________________ County, Minnesota My commission expires _______________________________KNOW ALL PERSONS BY THESE PRESENTS: That Brenda Lano Wolke as Trustee of the West Hennepin Affordable Housing Land Trust, A Minnesota non-profit corporation, owner of the following described property: Lots 10 and 11, Block 6, WEST MINNEAPOLIS HEIGHTS.Has caused the same to be surveyed and platted as WHAHLT ESTATES and does hereby dedicate to the public for public use the drainage and utility easements as created by this plat.In witness whereof said Brenda Lano Wolke as Trustee of the West Hennepin Housing Land Trust, a Minnesota non-profit corporation, has caused these presents to be signed by its proper officer this this _______ day of ____________________, 20____. Signed: West Hennepin Affordable Housing Land Trust By _____________________________________________ its ________________________________ Brenda Lano WolkeSTATE OF MINNESOTACOUNTY OF ________________This instrument was acknowledged before me this ______ day of __________________, 20____, by Brenda Lano Wolke its __________________________ of the West Hennepin Affordable Housing Land Trust, a Minnesota non-profit corporation, onbehalf of the corporation. Signature of Notary __________________________________ (Notary's Printed Name)_______________________________ Notary Public, ________________________ County, Minnesota My commission expires _______________________________CITY REVIEWBEARING REFERENCE:FOR THE PURPOSES OF THIS PLAT THE SOUTH LINE OFLOT 11, BLOCK 6, WEST MINNEAPOLIS HEIGHTS ISASSUMED TO BEAR NORTH 89°02'33" EAST.SCALE IN FEET0402060DENOTES 1/2 INCH BY 14 INCH IRON PIPE MONUMENT SET ANDMARKED BY LICENSE NUMBER 24992, UNLESS OTHERWISE NOTED.DENOTES FOUND OPEN END 1/2 INCH IRON PIPE MONUMENT,UNLESS OTHERWISE NOTED.7601 73rd Avenue NorthMinneapolis, Minnesota 55428(763) 560-3093DemarcInc.comPage 73 of 93
F:\survey\west minneapolis heights - hennepin\10-11-6 west minneapolis heights\01 Surveying - 90871\01 CAD\01 Source\01 Survey Base.dwgFile No.F.B. No. xxxx inv. 90871AWest Hennepin Affordable Housing5100 Thimsen AVENUE #120Minnetonka, MN 55345 Legal Description Signed: ____________________________________________ Gregory R. Prasch Registration No. 24992R-1 Lots within 500 feet of Subject Property7601 73rd Avenue NorthMinneapolis, Minnesota 55428(763) 560-3093DemarcInc.comWhahlt EstatesMiscellaneous Notesdrawn by:AHSurveyor:DemarcSurveying and Engineering7601 73rd Avenue N.Brooklyn Park, MN 55428Attn: Greg Praschphone: 763-560-3093fax: 763-560-3522e-mail: gregprasch@demarcinc.comProperty Address:316 Madison Avenue S, Edina, MN 55343Property Identification Number:3011721220025Total Area of Parcel = 11,992 sq.ftMN 1MN 2MN 3MN 4Personnel Property Owner:West Hennepin AffordableHousing Land Trust5100 Thimsen AVENUE #120Minnetonka, MN 55345Whahlt EstatesLot 11, Block 6, WEST MINNEAPOLIS HEIGHTSHennepin County, MinnesotaLot areas are shown from Hennepin County Tax Records.Lot Area: Mean = 8369.99 Median = 8120Lot Width: Mean = 63.22 Median = 60Lot Depth: Mean = 130.77 Median = 130.57Developer:West Hennepin AffordableHousing Land Trust5100 Thimsen AVENUE #120Minnetonka, MN 55345Attn: Brenda Lano Wolke952.401.7071MN 5Lot width means the horizontal distance between side lot lines, measured at rightangles to the line establishing the lot depth at a point of 50 feet from the front lotline.Lot depth means the horizontal distance between the midpoint of the front lot line andthe midpoint of the rear lot line. The greater frontage of a corner lot is its depth and thelesser frontage is its width.MN 6Page 74 of 93
Page 75 of 93
CITYVILLAGEEDINAEAS(1200)
15 k5 Ac
St
ME
N. 1/2 SEC.30, T.I17, R. 21.
NO 1143
TROLLEYL2
ALEY'S
Ava
5 6.86 Ac
ANSON'S
ADD
(4000)
26410 Res
EDINA Cify er HopkusSPRUCE
82 23
ROAD
2
3 3 8 3 4 3 $3 6
4.0 195 175 7 WILHOIT's412
ADD5
ME
4.25 Ac 3
3
400 492.31 L'AMPE'S
ASSN.
OF LOTS
(3800)WILLARD'S SUB D
330 A
REGISTERED
LAND
B
SURVEY
NO. 246
SUMMIF
GRAND
RAND
VIEW
VIE
PARK CEMETERY
EW
(VACATЕ
-1292.07 Res.
0600)
DE BLOCK 17
MENDEL
2200)
259 A Henry GladESE
ED)F. Ms Dael
13 14
(3690)
15
(2000)
20.28 Ac.C.W.Loufek
295 Ac
179 Ac.
C.W.Loufek
215 Ac.
3216
(3000)
50
--1296.93 Res.
15
BELMORE
2
GRIFART OF
3
23
LANE
325RONNEI'S FIRST
ADDITION
REARRANGEMENT
BLOCK 23
MENDELSSOHN
POND
(Aerial Photo)
9
RANCHO42.43
INTERLACHEN
ASCENSION
Block 1
ADDITION
29
WAYNE
TERRACE
SCHAFFERCOUNTY
MIRROR3
LAKE
23
LOTSUB.NO. 248J.E.BoAC
RO
A
D
ROAD RoT
e
l
s
TO
W
N RDMer
i
a
l
Pha
d
e
NO. 20
ELMER 4. -PETERSON
COUNTSURVEYOR
HENNEPIN COUNTY, MIM
24
32230
Page 76 of 93
EdinaMN.gov
316 Madison Avenue Subdivision with Variances
June 25, 2025
Page 77 of 93
Page 78 of 93
Page 79 of 93
Requests
1.Preliminary and final plat to re-plat the property into two lots
2.Variance from Sec. 36-437 of the Edina City Code to allow lot area of 5,988 sq. ft.
and 6,004 sq. ft. where 9,000 sq. ft. is required
3.Variance from Sec. 36-437 of the Edina City Code to allow lot width of 45.96 feet
for both lots where 75 feet is required
4.Variance from Sec. 36-437 of the Edina City Code to allow lot depth of 130.27 feet
for one of the lots where 130.57 feet is required.
Page 80 of 93
Page 81 of 93
Page 82 of 93
Page 83 of 93
Page 84 of 93
Page 85 of 93
Page 86 of 93
Page 87 of 93
Variance Criteria
Minnesota Statutes and Section 36-98 of the Edina Zoning Ordinance require that a
variance shall not be granted unless the following findings are made:
1.The variance would be in harmony with the general purposes and intent of the ordinance.
2.The variance would be consistent with the Comprehensive Plan.
3.There are practical difficulties in complying with the ordinance. The term “practical difficulties”
means the following:
i.The property owner proposes to use the property in a reasonable manner not permitted by the Zoning
Ordinance.
ii.The plight of the landowner is due to circumstances unique to the property not created by the
landowner.
iii.The variance, if granted, will not alter the essential character of the locality.
Page 88 of 93
Staff Findings
•The lots in the neighborhood were platted prior to Edina’s existing standards for lot area, width and depth.
•Lots in the original West Minneapolis Heights Plat were approximately 130’ x 46’
Page 89 of 93
Staff Findings
•The property was originally
platted as two lots. The
proposed plat would re-
establish the original lot sizes.
•12 of the 18 other properties
on the block have
approximately the same
dimensions as those being
proposed.
•The minimum lot standards do
not reflect the existing
characteristics of the
neighborhood.
Address #Width Depth Are a
300 82 130.78 10,788
303 92 131.69 12,098
304 52 130.72 6,832
305 46 131.47 6,041
306 50 130.68 6,561
307 46 131.36 6,036
308 92 130.64 12,060
309 46 131.25 6,031
311 46 131.14 6,026
312 92 130.57 12,039
313 46 131.03 6,021
315 46 130.91 6,016
317 46 130.8 6,011
319 46 130.69 6,006
320 46 130.44 6,002
321 46 130.58 6,001
322 46 130.4 5,997
323 46 130.47 5,996
Page 90 of 93
Staff Findings
•The request would advance the following Comprehensive Plan goals:
Land Use Chapter
•Goal 1: Encourage infill and redevelopment that optimizes use of city infrastructure, complement community character, and respond to
needs at all stages of life.
Housing Chapter
•Goal 2: Encourage the development and maintenance of a range of housing options affordable to residents at all income levels and life
stages.
o Promote owner-occupied units over rental units when providing affordable housing.
•Goal 4: Support the development of a wide range of housing options to meet the diverse needs of and preferences of the existing and
future Edina community.
o Retain and expand housing ownership options, while also supporting a balance between ownership and rental households.
Page 91 of 93
Staff Recommendation
Recommend the City Council approve of the plat and variances subject to the following conditions:
1.Compliance with the tree protection requirements in Section 10-82 of the City Code.
2.Prior to issuance of a building permit, the following items must be submitted:
a.Evidence that the final plat has been filed with Hennepin County. If the plat is not filed with Hennepin
County within one year from the date of approval by the City Council, the plat shall be deemed
abandoned and of no effect.
b.Submit evidence of a Nine Mile Creek Watershed District approval.
c.Driveway Entrance permit must be obtained from the Edina Engineering Department.
d.Utility hook-ups are subject to review by the City Engineer.
Deadline for a City decision: September 23, 2025.
Page 92 of 93