HomeMy WebLinkAbout(240) Flared End SectionTIE LAST 3 PIPE JOINTS. USE 2 TIE
BOLT FASTENERS PER JOINT INSTALLED
AT 60 DEGREES FROM TOP OF PIPE.
CONCRETE APRON PER
MnDOT STD. PLT
31000 OR 3110G.
RIPRAP PER MnDOT
PLT. 3133D.
PROVIDE 3 CLIPS TO FASTEN TRASH GUARD TO
FLARED END. HOT DIP GALVANIZE AFTER FABRICATION.
NOTES:
PLAN VIEW
BAR
SIZE
BOLT
SIZE
PIPE
SIZE
18" 3/4" 4" 5/8"
71" to 42" 1' 6" 3/4"
48" to 72" 1 1/4" 12" 1"
SAND FILTER
BLANKET
FILTER FABRIC
TRASH GUARDS TO BE INSTALLED ON 18" OR LARGER SIZED INLETS.
TRASH GUARDS MAY BE INSTALLED ON OUTLETS AT THE
DISCRETION OF THE ENGINEER.
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
FLARED END SECTION REVISED:
1-19
STANDARD
PLATE
240
ANCHOR BOTH SIDES
SIDE NEW
UNDER FULL LENGTH
OF FLARED END SECTION SAND FILTER
BLANKET
12" RIP—RAP
FILTER FABRIC
FCTION A-A
APPROVED: CITY ENGINEER