Loading...
HomeMy WebLinkAbout(300) Sewer and Water Service ConnectionWATER MAIN LOOP FOR SETTLEMENT WATER SERVICE 22 ' MA CONCRETE BRICK 4" OR 6" PVC SDR 26 SEWER SERVICE PIPE. MIN SLOPE 1/4" PER Ft (2,0%) SANITARY SERVICE WYE AT A 2 O'CLOCK POSITION. SANITARY SEWER NOTES: ANY CURB STOP LOCATED IN BLACKTOP OR CONCRETE DRIVEWAY OR SIDEWALK SHALL BE COVERED WITH METER BOX COVER (FORD A-1) OR APPROVED EQUAL. ALL WATER SERVICES SHALL BE 1" MIN., TYPE K COPPER, AND SHALL USE A SMITH BLAIR STAINLESS STEEL SADDLE TYPE #317 OR #372, OR APPROVED EQUAL WATER SERVICE MUST BE CONTINUOUS WITH NO JOINTS UNLESS SERVICE IS OVER 100' LONG. SANITARY AND WATER SERVICE LINES SHALL BE INSTALLED IN THE SAME TRENCH WITH 3' OF SEPARATION. a. EXCESSIVE SANITARY SEWER MAIN-LINE DEPTH SHALL BE REVIEWED AND APPROVED BY THE ENGINEER, cf_ VARIES (SEE PLAN) rc 1' 12' CURB BOX SHALL BE MUELLER H-10300 MINNEAPOLIS PATTERN 1 1/4" STACK FOR USE WITH 1" CURB STOP (DO NOT USE STATIONARY ROD). VARIES (SEE PLAN) ADJUST CURBSTOP TO 1" BELOW FINISHED GRADE 2 > c$ hi 1" CURB STOP SHALL BE MUELLER H-15154 MINNEAPOLIS PATTERN OR APPROVED EQUAL ALL STOPS SHALL BE FLARED FOR BOTH INLET & OUTLET. CORPORATION STOP SHALL BE MUELLER H-15000 OR APPROVED EQUAL WITH MUELLER THREAD FLARE TYPE JOINT. EX. COPPER HOUSE SERVICE CITY OF EDINA ENGINEERING & PUBLIC WORKS DEPTS. SEWER AND WATER SERVICE CONNECTIO 7:41 11 /Wit APPROVED: CITY ENGINEER REVISED: 1-18 STANDARD PLATE 300