HomeMy WebLinkAbout(300) Sewer and Water Service ConnectionWATER MAIN
LOOP FOR SETTLEMENT
WATER SERVICE
22 ' MA
CONCRETE BRICK
4" OR 6" PVC SDR 26 SEWER SERVICE
PIPE. MIN SLOPE 1/4" PER Ft (2,0%)
SANITARY SERVICE WYE AT
A 2 O'CLOCK POSITION.
SANITARY SEWER
NOTES:
ANY CURB STOP LOCATED IN BLACKTOP OR CONCRETE DRIVEWAY
OR SIDEWALK SHALL BE COVERED WITH METER BOX COVER
(FORD A-1) OR APPROVED EQUAL.
ALL WATER SERVICES SHALL BE 1" MIN., TYPE K COPPER, AND
SHALL USE A SMITH BLAIR STAINLESS STEEL SADDLE TYPE #317 OR
#372, OR APPROVED EQUAL
WATER SERVICE MUST BE CONTINUOUS WITH NO JOINTS UNLESS
SERVICE IS OVER 100' LONG.
SANITARY AND WATER SERVICE LINES SHALL BE INSTALLED IN THE
SAME TRENCH WITH 3' OF SEPARATION.
a.
EXCESSIVE SANITARY SEWER MAIN-LINE DEPTH SHALL BE REVIEWED
AND APPROVED BY THE ENGINEER,
cf_ VARIES (SEE PLAN)
rc
1'
12'
CURB BOX SHALL BE MUELLER
H-10300 MINNEAPOLIS PATTERN
1 1/4" STACK FOR USE WITH 1"
CURB STOP (DO NOT USE
STATIONARY ROD).
VARIES (SEE PLAN) ADJUST CURBSTOP TO 1"
BELOW FINISHED GRADE
2
>
c$
hi
1" CURB STOP SHALL BE
MUELLER H-15154 MINNEAPOLIS
PATTERN OR APPROVED EQUAL
ALL STOPS SHALL BE
FLARED FOR BOTH INLET & OUTLET.
CORPORATION STOP SHALL BE
MUELLER H-15000 OR APPROVED
EQUAL WITH MUELLER THREAD
FLARE TYPE JOINT. EX. COPPER
HOUSE SERVICE
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
SEWER AND WATER SERVICE
CONNECTIO
7:41 11 /Wit
APPROVED: CITY ENGINEER
REVISED:
1-18
STANDARD
PLATE
300