HomeMy WebLinkAbout(301) Sewer and Water Service Connection with Riser22 MAX WATER SERVICE
CONCRETE BRICK
CORPORATION STOP SHALL BE MUELLER
H-15000 OR APPROVED EQUAL WITH MUELLER
THREAD FLARE TYPE JOINT.
ci rc
VARIES (SEE PLAN)
VARIES (SEE PLAN)
STEEL FENCE POST
CURB BOX SHALL BE MUELLER
H-10300 MINNEAPOLIS PATTERN
1 1/4" STACK FOR USE WITH 1"
CURB STOP (DO NOT USE
STATIONARY ROD).
I
MAZER
7.5' MIN
WATER MAIN
1" CURB STOP SHALL BE
MUELLER H-15154 MINNEAPOLIS
PATTERN OR APPROVED EQUAL
AU. STOPS SHALL BE FLARED FOR
BOTH INLET & OUTLET.
(111
MIN SLOPE 1/4.
PER FT. (2.0%)
STUB
ELEV.
4" OR 6" PVC SDR 26
SEWER SERVICE PIPE.
45' SANITARY SERVICE WYE
TURNED UP AT A 45'
SANITARY SEWER
NOTES:
ANY CURB STOP LOCATED IN BLACKTOP OR CONCRETE DRIVEWAY
OR SIDEWALK SHALL BE COVERED WITH METER BOX COVER
(FORD A-1) OR APPROVED EQUAL.
ALL WATER SERVICES SHALL BE 1" MIN., TYPE K COPPER, AND
SHALL USE A SMITH BLAIR STAINLESS STEEL SADDLE TYPE #317 OR
#372, OR APPROVED EQUAL
WATER SERVICE MUST BE CONTINUOUS WITH NO JOINTS UNLESS
SERVICE IS OVER 100' LONG.
SANITARY AND WATER SERVICE LINES SHALL BE INSTALLED IN THE
SAME TRENCH WITH 3' OF SEPARATION.
EXCESSIVE SANITARY SEWER MAIN-UNE DEPTH SHALL BE REVIEWED
AND APPROVED BY THE ENGINEER.
SANITARY SEWER SERVICE RISER SHALL BE BACKFILLED WITH
GRANULAR MATERIAL AND COMPACTED.
CITY OF EDINA
ENGINEERING
& PUBLIC
WORKS
DEPTS.
SEWER AND WATER SERVICE
CONNECTION W RISER
APPROVED: CITY ENGINEER
REVISED:
1-18
STANDARD
PLATE
301