Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
(618) Postop Lantern
180' 0' 12" BOLT CIRCLE 10" BOLT CIRCLE 90' 16" BASE 9" OPENING 270' ACCESS DOOR LOCATION POSTOP LANTERN APPROVED: CITY ENGINEER UTILITY POSTOP LED LATERN WITH FULL CUTOFF OPTICS HOLOPHANE PUCL2—P30-30K—AS—BK—L3—S—FPD80 STANDARD COLOR IS BLACK ("BK"). FOR COLOR, CHANGE "BK" TO: BZ FOR BRONZE RAL6005 FOR DARK GREEN FOR 20A WR—RATED GFI RECEPTACLE ADD FGIUS—SXXH (OPTIONAL — SEE PLAN) ANCHORAGE DETAIL CHARLESTON FLUTED POLE HOLOPHANE #CH—A-14.5—F5J-16—P07—ABG—BK STANDARD COLOR IS BLACK ("BK"). FOR COLOR, CHANGE "BK" TO: BZ FOR BRONZE RAL6005 FOR DARK GREEN BOLT CIRCLE 10" TO 12" 3/4" ANCHOR BOLTS APPROVED LIGHT BASE FOUNDATION: MILLERBERND # 490A111 SCREW—IN ANCHOR BASE, OR MnDOT CONCRETE LIGHT FOUNDATION DESIGN E MOD (SEE PLAN FOR DETAIL) REVISED: 3-19 CITY OF EDINA ENGINEERING & PUBLIC WORKS DEPTS. STANDARD PLATE 618 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/28/18 Specifications are subject to change without notice. PUCL2 Page 1 of 5 PUCL2 Utility Postop Series Luminaire Full Cutoff LED2 Catalog Number Notes Type Mechanical • Heavy grade A360 cast aluminum (<1% copper)• Tool-less access with a spring-loaded latch• Hidden hinge door allowing the door to swing open andremain open • Optional internal or external NEMA twist lock photocontrol receptacle. Housing contains a tempered glass window to allow light to reach the cell for internal versions.• Mount to slip-fitter that will accept 3” high by 2-7/8” to • 3-1/8” O.D. pole tenon • Decorative top cover contains stainless steel hinge which secures entry the LED optical chamber• Polyester power coat paint to ensure maximum durability• Finish meets 5,000-hour salt spray testing• Holophane and RAL Classic finishes. Electrical • All surge protection meets ANSI/IEEE C62.41.2 10kV/10kA.• Standard SPD meets 10kV/5kA per ANSI C136.2-2015.• 20KV Option meets 20kV/10kA per ANSI C136.2-2015.• Quick disconnect connectors for ease of installation and maintenance. • Three pole terminal block is standard, with optionalprewired leads for ease of installation• LED drivers meet maximum total harmonic distortion (THD) of 20%, >0.90 Power Factor and are ROHS compliant. Minimum operating temperature is -40C. Electronic driver has an estimated minimum life of 100,000 hours at 25°C. Optical• IP65 rated optical compartment• LED circuit board located in the top cover • Asymmetric or Symmetric full cutoff distributions • 2700K, 3000K, 4000K, and 5000K CCT • 70CRI Standard Control Options • Field Adjustable Output (AO) module - Onboard device that adjusts the light output and input wattage to meet sitespecific requirements. The AO module is preset at the factory to position number 8 (see chart). • Wireless remote control for monitoring performance and/or maintenance of the system – ROAM• Factory Programmed Driver (FPDxx) - Customize lumenoutput prior to manufacturing and still enables control leads so other options can also be used • Long Life Photocontrols (PCLL) - 20 Year Life • 3 and 7 pin photocontrol receptacles internally (P3, P7) or externally (P3E, P7E) mounted• Part-night dimming (PND) enables luminaire to monitorand adjust 50% lumens based on season and geographic location, 8-day rolling average Testing/Compliance• UL 1598 - Wet Locations Safety Listing• Suitable for ambient temperatures -40°C to 40°C• DesignLights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check with the DLC Qualified Products List at www.designlights.org/QPL for updated list Manufacturing• Manufactured in Crawfordsville, Indiana, ARRA compliant • 100% electrical testing on all luminaires before shipment • Ten (10) years minimum experience in manufacturing LED based products Warranty5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_ Conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application.All values are design or typical values, measured under laboratory conditions at 25°C Specifications subject to change without notice.2'-10"Ø1'-5" LUMINAIREHOUSING OPTICALASSEMBLY CAST ALUMINUMFINIAL COVERLATCH SLIPFITTER FORNOMINAL 3" DIA.TENON SET SCREWS PHOTOCELLWINDOWOPPOSITE DOOROPENING HINGED DOOR HOUSING ELECTRONIC MODULEWITH TWISTLOCKRECEPTACLE(OPTIONAL) DIMENSIONAL DATA Maximum Weight - 39 lbs Maximum Effective Projected Area - 1.24 sq. ft. Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/28/18 Specifications are subject to change without notice. PUCL2 Page 2 of 5 PUCL2 Utility Postop Series Luminaire Full Cutoff LED2 Series Led performance package LED Color temperature Voltage Housing color Optics Finial PUCL2 Utility Postop LED FCO P10 1,500 nominal lumens (amber only) P20 4,500 nominal lumens P30 6,500 nominal lumens P40 8,500 nominal lumens P50 11,500 nominal lumens AM True amber 27K 2700K CCT 30K 3000K CCT 40K 4000K CCT 50K 5000K CCT AS Auto-sensing voltage (120 thru 277) 50/60 HZ AH Auto-sensing voltage (347 thru 480) 50/60 HZ BK Black GR Gray GH Graphite GN Green PP Prime paint WH White BZ Bronze TDC RAL Color color (RAL**) CMC Custom color match L2 Type 2 distribution full cutoff L3 Type 3 distribution full cutoff L4 Type 4 distribution full cutoff L5 Type 5 distribution full cutoff N None B Ball S Spike Options: Option Compatibility Matrix on page 3 of 4 AO Field Adjustable Output DE ROAM Hardware DecoNode and DCM Factory Installed FPDxx Factory Programmed Driver P3 NEMA Twist Lock photocontrol receptacle - 3 PIN receptacle only. P7 NEMA Twist Lock Dimming photocontrol receptacle - 7 PIN receptacle only. PCS DTL twistoff photocontrol for solid-state lighting 120-277V PCLL DTL long life twistlock photocontrol for solid-state AS P34 DTL long life twistlock photocontrol for solid-state 347V P48 DTL twistlock photocontrol 480V PND DTL long life twistlock photocontrol for solid-state 480V P3E NEMA Twist Lock Dimming Photocontrol Receptacle - 3 PIN. Externally mounted P7E NEMA Twist Lock Dimming Photocontrol Receptacle - 7 PIN. Externally mounted RME ROAM Node (External) RME3 347V ROAM NODE (External) RME4 480V ROAM NODE (External) PSC Shorting cap HSS House side shield L1H 1.5 ft prewired leads L03 3ft prewired leads L10 10 ft prewired leads L20 20 ft prewired leads L25 25 ft prewired leads L30 30 ft prewired leads NL1X1 NEMA Label 1" X 1" NL2X2 NEMA Label 2" X 2" 20KV 20kV/10kA surge protection ORDERING INFORMATION Example: PUCL2 P20 30K AS GN L2 N P7E Accessories: Order as separate catalog number. XXCL2HSS1 Field Accessory - Louvered house side shield (Qty 1) XXCL2HSSJ50 Field Accessory - Louvered house side shield (Bulk Qty 50) XXCL2SPD10KAS 10kV/5kA Extreme surge 120-277V XXCL2SPD10KAH 10kV/5kA Extreme surge 480V XXCL2SPD20KAS 20kV/10kA Extreme surge 120-277VV XXCL2SPD20KAH 20kV/10kA Extreme surge 480V FINIAL INFORMATION Mark Appropriate Box for Finial Options Spike Ball No Finial Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/28/18 Specifications are subject to change without notice. PUCL2 Page 3 of 5 PUCL2 Utility Postop Series Luminaire Full Cutoff LED2 PROJECTED LED LUMEN MAINTENANCE Data references the extrapolated performance projections for the platforms noted in 25C ambient, based on 6,000 hours of lED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. LUMEN AMBIENT TEMPERATURE (LAT) MULTIPLIERS Use the factors to determine relative lumen output for average ambient temperatures from 0-40C (32-104F) OPTIONS MATRIX Package Lumen Maintenance L70 Hrs25k hrs 36k hrs 50k hrs 60k hrs 75k hrs 100k hrs P20-P40 0.97 0.96 0.95 0.94 0.93 0.91 383,000 P50 0.96 0.94 0.93 0.91 0.90 0.87 267,667 Ambient Temp (degrees C) Lumen Multiplier 0 5 10 15 20 25 30 35 40 1.05 1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.97 Mounting SELECTED OPTION (start here) AO DE FPDxx P3 P3E P7 P7E P34 P48 PCLL PCS PND PSC RME RME3 RME4 20kV LED Performance Package P10 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y P20 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y P30 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y P40 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y P50 Y N Y Y Y Y Y Y Y Y Y N Y Y Y Y N Voltage AS Y Y Y Y Y Y Y N N Y Y Y Y Y N N Y AH Y N Y Y Y Y Y Y Y Y N N Y N Y Y Y Finial B Y Y Y Y N Y N Y Y Y Y Y Y N N N Y S Y Y Y Y N Y N Y Y Y Y Y Y N N N Y N Y Y Y Y M Y M Y Y Y Y Y Y M M M Y Compatible Options AO N Y Y Y F F Y Y Y Y N Y N N N Y DE N Y Y N N N N N N N N Y N N N Y FPDxx Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y P3 F M Y N N N Y Y Y Y M Y N N N Y P3E F N Y N N N Y Y Y Y N Y N N N Y P7 F N Y N N N Y Y Y Y N Y N N N Y P7E F N Y N N N Y Y Y Y N Y I I I Y P34 Y N Y Y Y Y Y N N N N N N N N Y P48 Y N Y Y Y Y Y N N N N N N N N Y PCLL Y N Y Y Y Y Y N N N M N N N N Y PCS Y N Y Y Y Y Y N N N M N N N N Y PND N N Y Y N N N N N M M Y N N N Y PSC Y N Y Y Y Y Y N N N N Y N N N Y RME N N Y N N N Y N N N N N N N N Y RME3 N N Y N N N Y N N N N N N N N Y RME4 N N Y N N N Y N N N N N N N N Y 20kV Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y = Valid Option Combination F = Future ready (wired with "AO", but could accept control device with tool-less field wiring) M = Must have: one of these must be installed for the luminaire to operate N = Combination Not available ROAM OPTION DETAILS DE = UL listed components without GPS capability, external antenna is black and includes ROAM capable node only, ROAM service package sold separately via Acuity ControlsRME = UL listed device without GPS capability, blue housing color, includes ROAM capable node only, ROAM service package sold separately via Acuity Controls and contact Acuity Controls for RME device with GPS capability or non-standard color RME3 = UL listed device without GPS capability, green housing color, includes ROAM capable node only, ROAM service package sold separately via Acuity Controls and contact Acuity Controls for RME device with GPS capability or non-standard color RME4 = UL listed device without GPS capability, yellow housing color, includes ROAM capable node only, ROAM service package sold separately via Acuity Controls and contact Acuity Controls for RME device with GPS capability or non-standard color Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/28/18 Specifications are subject to change without notice. PUCL2 Page 4 of 5 PUCL2 Utility Postop Series Luminaire Full Cutoff LED2 LED Package Distribution System Watts 2700K 3000K 4000K 5000K Lumens LPW Lumens LPW Lumens LPW Lumens LPW P20 L2 45 4633 103 4734 105 5218 116 5375 119 L3 45 4101 91 4190 93 4618 103 4758 106 L4 45 4414 98 4510 100 4971 110 5121 114 L5 45 4500 100 4598 102 5068 113 5221 116 P30 L2 66 6711 102 6857 104 7557 115 7785 118 L3 66 5940 90 6069 92 6689 101 6891 104 L4 66 6394 97 6533 99 7200 109 7418 112 L5 66 6518 99 6660 101 7340 112 7562 115 P40 L2 89 8528 96 8714 98 9604 108 9894 111 L3 89 7549 85 7714 87 8501 96 8758 98 L4 89 8125 91 8303 93 9151 103 9427 106 L5 89 8283 93 8464 95 9329 105 9610 108 P50 L2 139 12327 89 12596 91 13882 100 14301 103 L3 139 10911 78 11149 80 12288 88 12658 91 L4 139 11744 84 12001 86 13226 95 13626 98 L5 139 11972 86 12234 88 13483 97 13890 100 PERFORMANCE DATA FPDXX DATA OPTIONS FPDxx Setting P20 27K P20 30K P20 40K P20 50K Wattage L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 Standard 45 4633 4101 4414 4500 4732 4190 4510 4598 5218 4618 4971 5068 5375 4758 5121 5221 FPD95 43 4401 3896 4193 4275 4497 3981 4285 4368 4957 4387 4722 4815 5106 4520 4865 4960 FPD90 41 4170 3691 3973 4050 4261 3771 4059 4138 4696 4156 4474 4561 4838 4282 4609 4699 FPD85 38 3938 3486 3752 3825 4024 3562 3834 3908 4435 3925 4225 4308 4569 4044 4353 4438 FPD80 36 3706 3281 3531 3600 3787 3352 3608 3678 4174 3694 3977 4054 4300 3806 4097 4177 FPDxx Setting P30 27K P30 30K P30 40K P30 50K Wattage L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 Standard 66 6711 5940 6394 6518 6857 6069 6533 6660 7557 6689 7200 7340 7785 6891 7418 7562 FPD95 63 6375 5643 6074 6192 6514 5766 6206 6327 7179 6355 6840 6973 7396 6546 7047 7184 FPD90 59 6040 5346 5755 5866 6171 5462 5880 5994 6801 6020 6480 6606 7007 6202 6676 6806 FPD85 56 5704 5049 5435 5540 5828 5159 5553 5661 6423 5686 6120 6239 6617 5857 6305 6428 FPD80 53 5369 4752 5115 5214 5846 4855 5226 5328 6046 5351 5760 5872 6228 5513 5934 6050 FPD75 50 5033 4455 4796 4889 5143 4552 4900 4995 5668 5017 5400 5505 5839 5564 5564 5672 FPD70 46 4698 4158 4476 4563 4800 4248 4573 4662 5290 4682 5040 5138 5450 5193 5193 5293 FPDxx Setting P40 27K P40 30K P40 40K P40 50K Wattage L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 Standard 89 8528 7549 8125 8283 8714 7714 8303 8464 9604 8501 9151 9329 9894 8758 9427 9610 FPD95 85 8102 7172 7719 7869 8278 7328 7888 8041 9124 8076 8693 8863 9400 8320 8956 9130 FPD90 80 7675 6794 7313 7455 7483 6943 7473 7618 8644 7651 8236 8396 8905 7882 8484 8649 FPD85 76 7249 6417 6906 7041 7407 6557 7058 7194 8163 7226 7778 7930 8410 7444 8013 8169 FPD80 71 6822 6039 6500 6626 6971 6171 6642 6771 7683 6801 7321 7463 7916 7006 7542 7688 FPDxx Setting P50 27K P50 30K P50 40K P50 50K Wattage L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 L2 L3 L4 L5 Standard 139 12327 10911 11744 11972 12596 11149 12001 12234 13882 12288 13226 13483 14301 12658 13626 13890 FPD95 132 11710 10365 11157 11374 11966 10591 11401 11622 13188 11673 12565 12809 13586 12026 12944 13196 FPD90 125 11094 9820 10570 10775 11336 10034 10801 11010 12494 11059 11904 12135 12871 11393 12263 12501 FPD85 118 10478 9274 9983 10176 10706 9476 10201 10399 11800 10444 11242 11461 12156 10760 11582 11807 FPD80 111 9861 8729 9395 9578 10076 8919 9600 9787 11106 9830 10581 10786 11441 10127 10900 11112 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/28/18 Specifications are subject to change without notice. PUCL2 Page 5 of 5 PUCL2 Utility Postop Series Luminaire Full Cutoff LED2 COMPONENTS & OPTIONS DATA AO Manual field adjustable output dimming device 20kV Safeguard your investment from extreme voltage spikes with our new Extreme 20kV/10kA SPD RME (External) Remote Asset Management Control Dimming Device (specify with receptacle) HSS Minimize backlight with a louvered house-side-shield. Available as a factory option or field accessory DE Remote Asset Management Control Decorative Node(specify with P3 receptacle US-2407 For information on specifying orientation and mounting heights see Orientation Guide in the back of the Accessories section in the catalog. ·Receptacle with Wet Location While Closed Cover Catalog part # FG-SXXH SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, UL Listed cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. Small, Wet Location while in use Cover (for use with two 3/8" max. dia. cords) Wet Location when closed Cover Duplex Receptacle with Ground Fault Interrupter Post Shaft Duplex Receptacle with Ground Fault Interrupter Large, Wet Location while in use Cover (for use with two 1/2" max. dia. cords) Duplex Receptacle with Ground Fault Interrupter LIFT OPEN Weatherproof Receptacles External, Post Shaft Location External receptacles are typically installed above pedestrian level for special event uses and docorative seasonal lighting. · Receptacle with Small, In-Use Wet Location Cover Catalog part # FGIUS-SXXH SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 410-57(b). The cover shall accept most common cord sets up to 3/8" diameter (14/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. ·Receptacle with Large, In-Use Wet Location Cover Catalog part # FGIUL-SXXH SPECIFICATION A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-8380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 410-57(b). The cover shall accept most common cord sets up to 1/2" diameter (12/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. · Ground Fault Circuit Interrupter Receptacles. · Test/Reset buttons on face of receptacles.· All Cast Aluminum Covers. Not Plastic. (Paintable to match post color). · Weatherproof "While in Use" covers in two sizes. LIFT OPEN 3/4" 2 3/8" 5 3/4" 3 3/8" 3 3/8" 2 7/8" 4 1/2" 3 3/8" 5 3/4"