Loading...
HomeMy WebLinkAboutRes Swimming pool SP026B-SubmittalReq ppr 04042017I:\Building\SafetyPoliciesInformation\2017\Website\Res Swimming pool SP026B-SubmittalReq ppr 04042017. For paper submittals only Purpose: Establish submission requirements at the time of permit application to enable accurate, timely review. Scope: All new residential buildings and residential building additions Site Address: ___________________________________________________________________________ Instructions: Please fill out completely before submitting your plans. The Building Inspections Department can be reached at 952.826.0372 from 7:00am – 4:30pm Monday through Friday. Required for Approval Check if Submitted General Items Yes 1.Completed City of Edina Permit Application Yes 2.Evidence of watershed’s permit application to apply. NOTE: Actual permit required for approval. Nine Mile Watershed District : www.ninemilecreek.org or MinnehahaCreek Watershed District: www.minnehahacreek.org Yes 3.Provide complete to scale plans and specs. a)Plumbing diagramb)Diving board, if applicable c)Stairs, ladders and swim outsd)Skimmer locations e)Inletsf)Main drain g)Cross section diagram of the swimming poolh)Proposed pool decks Yes 4.A site survey complying with City Survey/Site Policy SP-005-B.a)Indicate a 14 foot setback from the water’s edge to rear and side yard property linesb)Indicate a 10 foot setback from water’s edge to utility lines, if applicable c)Indicate the location of recirculation equipment. A 10 foot setback fromproperty lines is required d)Indicate the location of fencing, including any gates Yes 5.Provide the following information:a)Make and model number of the filter and pump b)Type of filter (sand, D.D., cartridge)c)Designed flow rate of recirculation system d)Liquid capacity of the poole)Type of handhold around the pool perimeter f)Make, model and description of chlorinator Yes 6.Additional permit and inspections required for electrical work from the State Yes 7.Additional mechanical permit and inspections required for pool heaterand pool heater gas lines Yes 8.Two signed copies of Storm Water Management Plan & Erosion Control Plan per City Engineer requirements. Comply with Erosion and Sediment Control forSingle/Double Dwelling Units Policy and Floodplain Development – Residential Policy.Contact the Engineering Department at 952-826-0371 for details. Yes 9.All swimming pools must have a four (4) foot wide, moisture impervious deck extending entirely around the pool. Concrete or its equivalent is acceptable. EDINA BUILDING SAFETY POLICY/INFORMATION1 Application Submittal Requirements Swimming Pool Plan Requirements subject Edina City Code Sec.10-487 code reference Inspections Department department approval SP026Bppr policy number 04/04/2017 revision date 9/25/14 effective date 1 of 2 page number I:\Building\SafetyPoliciesInformation\2017\Website\Res Swimming pool SP026B-SubmittalReq ppr 04042017. Yes 10.Applicant shall be responsible for erecting and maintaining at least a four (4)foot in height fence with self-closing, self-latching gate(s) installed around the pool. Yes 11.Call for the following required inspections when ready:a)Footing: Before pouring, Call Building Inspections Department at 952 826 0372b)Electrical: State Electrical Inspector – Doug Torvund at 612 866 5895 c)Plumbing air test, pool heater and gas piping Call BuildingInspections Department at 952 826 0372 d)Final swimming pool inspection: Health Department at 952 826 046 12.Provide a Tree Protection Plan per (Ordinance No. 2014-25) Yes 13.Swimming pool may not be filled without fencing in place Yes 14.Swimming pool may not be used before final inspection approval. Plans will be reviewed and approved by the Planning, Engineering and Building Department. Plan review time will vary, but in all cases permit applicants should allow at least two weeks of plan review time if and when all the correct information is dropped off. I acknowledge that the items checked on the list above are included on or with the submitted plans: Contractor:____________________________________________________________________ Contact person: ___________________ Signature: _____________________________________________________________________________________________________ Phone Number:_____________________________________ Email_______________________________________________________